FireCADCalc

Fuel Oil Heater Duty and Steam Consumption

Heat and steam needed to heat furnace oil or LSHS to pumping or atomising temperature, from oil flow, specific heat, temperatures and heat-loss allowance.

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Fuel oil and gas systemBurner and furnace

Inputs

Examples: 1.5 t/h furnace oil 40 to 110 °C, 10 % loss, 7 bar(a) steam0.3 t/h, 30 to 95 °C, 15 %, 4 bar(a)10 t/h LSHS 60 to 130 °C, 8 %, 10 bar(a)

From the oil supplier; heavy fuel oils are roughly 1.8–2.1 kJ/(kg·K) over this range.
Heater and pipework losses as a share of the oil duty; 10 % is a FireCAD starting value, not a published figure.
Shown as gauge (bar g, kg/cm² g, psig) as plant headers read; choose an absolute unit to enter absolute pressure.

Results

Heater duty430.50kW
Steam consumption769.35kg/h
Steam saturation temperature179.89°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1.5 t/h furnace oil 40 to 110 °C, 10 % loss, 7 bar(a) steam. The inputs, in the units selected above:

InputValue
Oil flow1,500.0 kg/h
Mean specific heat of the oil1.9500 kJ/(kg·K)
Oil temperature in40.000 °C
Oil temperature out (atomising or pumping)110.00 °C
Heat-loss allowance10.000 %
Heating steam pressure (saturated)5.9867 bar g

Applying the formula below gives:

ResultValue
Heater duty62.562 kW
Steam consumption109.04 kg/h
Steam saturation temperature164.95 °C

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_o\,c_p\,(T_2 - T_1)\,(1 + \lambda) \qquad \dot m_s = \frac{\dot Q}{h_{fg}(p_s)}\)

Variables

Symbol Meaning SI unit
\(\dot m_o\) oil flow kg/s
\(c_p\) mean specific heat of the oil J/(kg·K)
\(T_1\) oil temperature in K
\(T_2\) oil temperature out K
\(\lambda\) heat-loss allowance –
\(p_s\) heating steam pressure (absolute in SI; shown as gauge) Pa
\(\dot Q\) heater duty W
\(\dot m_s\) steam consumption kg/s
\(T_{sat}\) steam saturation temperature K
\(h_{fg}\) latent heat at \(p_s\) (IF97) J/kg

Method and standards

Energy balance of the oil; steam condenses at saturation and leaves as saturated condensate (FireCAD IAPWS-IF97).

Where it is used

  • Sizing oil preheaters for burners.
  • Steam budgets of oil-fired boiler houses.
  • Choosing heating steam pressure.

Common mistakes

  • Using too low a steam pressure: the oil outlet must be well below the steam's saturation temperature.
  • Forgetting the recirculation flow back to the tank.
  • Using the specific heat of water.

Assumptions and limits

  • Condensate leaves saturated (no subcooling); constant specific heat.
  • The heat-loss allowance multiplies the oil duty; its 10 % default is a starting value, not a published one.
  • The steam pressure is shown as gauge; the 15 K approach warning is a FireCAD rule of thumb.

References

  • IAPWS R7-97(2012) IF97
  • first law of thermodynamics

Questions and answers

How much steam does a fuel oil heater use?

The oil's heat gain divided by the steam's latent heat. 1.5 t/h of furnace oil from 40 to 110 °C at 1.95 kJ/(kg·K) with a 10 % loss allowance takes 62.6 kW, about 109 kg/h of steam at 7 bar(a).

What temperature does the oil need?

The temperature that brings it to the burner's atomising viscosity; the viscosity calculator finds it from two known points.

Electric or steam heating?

Electric heaters start a cold plant; steam heaters run it once steam is available, at a fraction of the cost.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.