Worked example
Example: Bituminous 30 t/h, 15 % moisture, 60 t/h air at 280 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Raw coal feed to the mill | 30.000 t/h |
| Total moisture of the raw coal | 15.000 % |
| Moisture left in the pulverised coal | 2.0000 % |
| Raw coal temperature | 30.000 °C |
| Specific heat of the dry coal | 1.2500 kJ/(kg·K) |
| Primary air flow, dry | 60.000 t/h |
| Primary air temperature at the mill inlet | 280.00 °C |
| Primary air humidity, kg water per kg dry air | 0.013000 kg/kg |
| Mill grinding power (enters as heat) | 150.00 kW |
| Heat lost from the mill casing and ducts | 50.000 kW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mill outlet temperature | 91.381 °C |
| Primary air (dry) to coal ratio | 2.0000 kg/kg |
| Water evaporated in the mill | 3.9796 t/h |
| Heat taken by drying and heating the coal | 3,394.7 kW |
Open this example in the calculator and change any input.
Formula
\(w = \frac{M_{in} - M_{out}}{1 - M_{out}}, \quad \dot m_w = \dot m_c w\)
\(Q_c = \dot m_w [h_v(T_o) - h_f(T_c)] + \dot m_c (1 - M_{in}) c_c (T_o - T_c) + \dot m_c (M_{in} - w) [h_f(T_o) - h_f(T_c)]\)
\(h_a(T) = h_{da}(T) + x_a h_{v,ig}(T), \quad \dot m_a [h_a(T_{in}) - h_a(T_o)] + P_m - Q_l = Q_c\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_c\) | raw coal feed | kg/s |
| \(M_{in}\) | total moisture of the raw coal | - |
| \(M_{out}\) | moisture left in the pulverised coal | - |
| \(T_c\) | raw coal temperature | K |
| \(c_c\) | specific heat of the dry coal | J/(kg·K) |
| \(P_m\) | mill grinding power, entering as heat | W |
| \(Q_l\) | mill casing and duct heat loss | W |
| \(\dot m_w\) | water evaporated | kg/s |
| \(Q_c\) | heat taken by the coal side | W |
| \(\dot m_a\) | primary air flow, dry air | kg/s |
| \(T_{in}\) | primary air temperature at the mill inlet | K |
| \(T_o\) | mill outlet temperature | K |
| \(r\) | primary air (dry) to coal ratio | kg/kg |
| \(h_v\) | water vapour enthalpy at T_o and 1 psia | J/kg |
| \(h_f\) | liquid water enthalpy | J/kg |
| \(h_a\) | humid air enthalpy per kg dry air: dry air plus x_a kg of ideal-gas water vapour | J/kg |
| \(x_a\) | primary air humidity, kg water vapour per kg dry air | kg/kg |
| \(h_{da}\) | dry air enthalpy | J/kg |
| \(h_{v,ig}\) | ideal-gas water vapour enthalpy | J/kg |
| \(w\) | water evaporated per kg raw coal | kg/kg |
Method and standards
A heat balance on the mill: the hot primary air gives up heat between the mill inlet and outlet temperatures; with the grinding power (which ends as heat) it evaporates the surface moisture and warms the coal and the water left in it. The evaporated water leaves as vapour (IAPWS-IF97 at 1 psia, as ASME PTC 4 treats flue gas moisture); the primary air is humid: per kg of dry air it carries x_a kg of water vapour, and its enthalpy is dry air plus that vapour as an ideal gas from NIST Shomate data, the basis ASME PTC 4 uses for moisture in air. The outlet temperature is found by solving the balance.
Where it is used
- Predicting mill outlet temperature after a change in coal moisture.
- Checking the air heater outlet needed for a target outlet temperature.
- Commissioning and tuning primary air control.
Common mistakes
- Using wet-basis and dry-basis moisture interchangeably.
- Forgetting the grinding heat.
- Treating the air to coal ratio as fixed across the load range.
Assumptions and limits
- Steady state; the primary air flow is dry air, and the humidity entered is carried as vapour.
- If the heat supplied exceeds the coal's need even at the inlet air temperature, the outlet is shown at that temperature with a note.
- Surface moisture removed is total moisture less the moisture left in the pulverised coal.
- No allowance for seal air or leakage.
References
- Mill heat balance
- IAPWS-IF97
- ASME PTC 4 (vapour at 1 psia)
Questions and answers
What outlet temperature will a mill reach?
In the example, 30 t/h of 15 % moisture coal with 60 t/h of air at 280 °C reaches about 91 °C at the outlet (primary air humidity 0.013 kg/kg).
What air to coal ratio do mills run at?
Roughly 1.5 to 2.5 kg air per kg coal for vertical spindle mills; the mill maker sets the curve against load.
Why limit the outlet temperature?
Hot, high-volatile coal dust can ignite in the mill and pipes; the limit falls as volatile matter rises.