Worked example
Example: 40 t/h coal, A/C 1.8, 320/35 → 250 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Coal flow to the mill | 40.000 t/h |
| Primary air-to-coal ratio | 1.8000 kg/kg |
| Hot air temperature (air heater outlet) | 320.00 °C |
| Cold (tempering) air temperature | 35.000 °C |
| Required mill inlet temperature | 250.00 °C |
| Air density at 0 °C, 1 atm | 1.2930 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Primary air flow | 72.000 t/h |
| Hot air | 54.316 t/h |
| Tempering air | 17.684 t/h |
| Hot air share | 75.439 % |
| Primary air at 0 °C, 1 atm | 55,684 Nm³/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_{PA} = (A/C)\dot m_c, \quad x_h = \frac{T_m - T_c}{T_h - T_c}, \quad \dot m_h = x_h\dot m_{PA}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_c\) | Coal flow to the mill | kg/s |
| \(A/C\) | Primary air-to-coal ratio | kg/kg |
| \(T_h\) | Hot air temperature (air heater outlet) | K |
| \(T_c\) | Cold (tempering) air temperature | K |
| \(T_m\) | Required mill inlet temperature | K |
| \(\rho_n\) | Air density at 0 °C, 1 atm | kg/m³ |
| \(\dot m_{PA}\) | Primary air flow | kg/s |
| \(\dot m_h\) | Hot air | kg/s |
| \(\dot m_t\) | Tempering air | kg/s |
| \(x_h\) | Hot air share | - |
| \(\dot V_n\) | Primary air at 0 °C, 1 atm | Nm³/s |
Method and standards
Mixing balance of hot and tempering air with one specific heat for both streams.
Where it is used
- Mill commissioning and tuning.
- Checking hot air damper limits.
Common mistakes
- Using the outlet temperature instead of the inlet.
- Ignoring seal air entering the mill.
Assumptions and limits
- Equal specific heats: the specific heat of air rises about 2–3 % from 35 °C to 320 °C, so the hot air share is slightly overstated.
- The normal density is your input (default 1.293 kg/m³, dry air at 0 °C and 1 atm).
References
- Mass and heat balance of air mixing (definitions); Babcock & Wilcox
- Steam: Its Generation and Use
- 41st ed. (2005)
- ch. 13 (coal pulverisers)
Questions and answers
What air-to-coal ratio is typical?
1.6–2.2 kg/kg for vertical spindle mills at full load, rising at low load to keep pipe velocities up.
Why temper the air?
Hot air from the air heater is too hot for the mill; cold air is mixed in to reach the inlet temperature the drying balance needs.
What do the defaults give?
40 t/h of coal at 1.8: 72 t/h of primary air, 75 % hot air at 320 °C and 25 % tempering air for a 250 °C mill inlet.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.