Worked example
Example: Coal elevator. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bucket volume (water level) | 4.2000 L |
| Fill factor | 75.000 % |
| Bucket spacing (pitch) | 0.30000 m |
| Belt or chain speed | 1.4000 m/s |
| Bulk density | 800.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volume throughput | 52.920 m³/h |
| Mass throughput | 42.336 t/h |
Open this example in the calculator and change any input.
Formula
\(\dot V = \frac{V_b \phi v}{s}, \quad \dot m = \rho_b \dot V\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_b\) | Bucket volume (water level) | m³ |
| \(\phi\) | Fill factor | - |
| \(s\) | Bucket spacing (pitch) | m |
| \(v\) | Belt or chain speed | m/s |
| \(\rho_b\) | Bulk density | kg/m³ |
| \(\dot V\) | Volume throughput | m³/s |
| \(\dot m\) | Mass throughput | kg/s |
Method and standards
Volumetric throughput from the definition: bucket volume times fill factor, times the number of buckets passing per second (\(v/s\)). The fill factor and speed are your inputs or the maker's figures; no published table is reproduced.
Where it is used
- Coal, husk and lime handling.
Common mistakes
- Struck volume used for water-level volume.
Assumptions and limits
- Steady feed. The speed is not checked against the discharge type (centrifugal or continuous) and the pitch is not checked against the bucket size; take both from the maker.
References
- Volumetric throughput V̇ = V_b φ v/s
Questions and answers
Fill factor?
Buckets are rarely full: 70–80 % is a common design assumption for free-flowing material; confirm it with the elevator maker.
Speed?
Centrifugal-discharge elevators run faster than continuous-bucket ones.
Sticky or fibrous material?
Bagasse and wet fines need other conveyors.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.