FireCADCalc

Biomass Fuel Storage: Mass, Volume and Energy for a Number of Days

Mass, volume and energy density of biomass fuel stored for a number of days, from boiler heat input, moisture, dry calorific value and bulk density.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)

Inputs

Examples: 20 MW on chips, 35 %, 15 daysRice husk 8 MW, 10 %, 7 days

Results

NCV as received = NCV_dry(1 − w) − 2.442 MJ/kg × w (evaporation of the moisture at 25 °C, IAPWS-IF97). The heat input must be on the NCV basis; a GCV-basis rating understates the fuel flow. Covered storage keeps moisture down; add 10–20 % volume for access and rotation.

Net calorific value as received12.806MJ/kg
Fuel flow2.2490t/h
Fuel to store377.83t
Storage volume3,148.6m³
Energy density of the stored fuel (NCV)426.86kWh/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20 MW on chips, 35 %, 15 days. The inputs, in the units selected above:

InputValue
Boiler fuel heat input (NCV basis, not GCV)20.000 MW
Operating hours per day24.000 h
Days of storage15.000 -
Net calorific value, dry basis18.000 MJ/kg
Moisture, wet basis35.000 %
Bulk density as stored (wet)250.00 kg/m³

Applying the formula below gives:

ResultValue
Net calorific value as received10.845 MJ/kg
Fuel flow6.6388 t/h
Fuel to store2,390.0 t
Storage volume9,559.8 m³
Energy density of the stored fuel (NCV)753.15 kWh/m³

Open this example in the calculator and change any input.

Formula

\(NCV = NCV_d(1 - w) - h_{fg,25}\,w, \quad \dot m_f = \frac{Q_{in}}{NCV}\)

\(M = \dot m_f\,h_d\,n, \quad V = \frac{M}{\rho_b}, \quad e_V = \rho_b\,NCV\)

Variables

Symbol Meaning SI unit
\(Q_{in}\) Boiler fuel heat input (NCV basis) W
\(h_d\) Operating hours per day s
\(n\) Days of storage -
\(NCV_d\) Net calorific value, dry basis J/kg
\(w\) Moisture, wet basis -
\(\rho_b\) Bulk density as stored (wet) kg/m³
\(NCV\) Net calorific value as received J/kg
\(\dot m_f\) Fuel flow kg/s
\(M\) Fuel to store kg
\(V\) Storage volume m³
\(e_V\) Energy density of the stored fuel (NCV basis) J/m³
\(h_{fg,25}\) latent heat of water at 25 °C (IAPWS-IF97), 2.442 MJ/kg

Method and standards

Mass and energy balance.

Where it is used

  • Biomass boiler fuel yards.
  • Seasonal fuel stocking.

Common mistakes

  • Using dry-basis NCV for wet fuel.
  • Ignoring compaction and settling.

Assumptions and limits

  • Uniform moisture.
  • The heat input is on the NCV basis. Boiler ratings are often on GCV; entering a GCV-basis input here understates the fuel flow and the storage.

References

  • Moisture correction of calorific value (definitions; latent heat 2.442 MJ/kg at 25 °C from IAPWS-IF97)

Questions and answers

Why does moisture matter so much?

Wet fuel carries less heat per tonne and needs some of it to evaporate its own water; at 50 % moisture a fuel gives well under half its dry heat.

What bulk densities are typical?

Rice husk 100–130 kg/m³, wood chips 200–350, bagasse 120–160, pellets 600–700.

What do the defaults give?

20 MW input on chips at 35 % moisture (NCV 10.8 MJ/kg): about 6.7 t/h, 2,400 t and 9,600 m³ for 15 days.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.