FireCADCalc

Fluidised-Bed Start-Up: Fuel to Heat the Bed

Fuel oil or gas to heat the bed material (and refractory) from cold to the solid-fuel ignition temperature with start-up burners of a given efficiency and time.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 150 t bed + 100 t refractory to 600 °CSmall AFBC

Results

Refractory heat-up rates are limited by the refractory maker's curve; that often sets the start-up time.

Heat to the bed and refractory128.82GJ
Start-up fuel6.1343t
Average fuel rate1,022.4kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 150 t bed + 100 t refractory to 600 °C. The inputs, in the units selected above:

InputValue
Bed material150,000 kg
Bed specific heat0.84000 kJ/(kg·K)
Refractory heated100,000 kg
Refractory specific heat1.0000 kJ/(kg·K)
Initial temperature30.000 °C
Ignition temperature for coal600.00 °C
Start-up burner heat transfer efficiency50.000 %
Start-up fuel LHV42.000 MJ/kg
Heating time6.0000 h

Applying the formula below gives:

ResultValue
Heat to the bed and refractory128.82 GJ
Start-up fuel6.1343 t
Average fuel rate1,022.4 kg/h

Open this example in the calculator and change any input.

Formula

\(Q = (M_bc_b + M_rc_r)(T_2 - T_1), \quad M_f = \frac{Q}{\eta_bLHV}, \quad \dot M_f = \frac{M_f}{t}\)

Variables

Symbol Meaning SI unit
\(M_b\) Bed material kg
\(c_b\) Bed specific heat J/(kg·K)
\(M_r\) Refractory heated kg
\(c_r\) Refractory specific heat J/(kg·K)
\(T_1\) Initial temperature K
\(T_2\) Ignition temperature for coal K
\(\eta_b\) Start-up burner heat transfer efficiency -
\(LHV\) Start-up fuel LHV J/kg
\(t\) Heating time s
\(Q\) Heat to the bed and refractory J
\(M_f\) Start-up fuel kg
\(\dot M_f\) Average fuel rate kg/s

Method and standards

Sensible heat balance.

Where it is used

  • Start-up fuel budgets.

Common mistakes

  • Ignoring refractory.
  • Assuming all burner heat reaches the bed.

Assumptions and limits

  • Uniform final temperature: the bed and the refractory are both taken to reach the ignition temperature.
  • Heat taken by the water walls, drum water and steam during the heat-up is not counted separately; it is folded into the burner heat transfer efficiency you enter.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 11 (start-up: bed heated by start-up burners to coal ignition temperature)
  • Sensible heat balance

Questions and answers

To what temperature?

Bituminous coal is fed at about 500–600 °C bed temperature; low-volatile fuels need more.

Why is efficiency so low?

Much burner heat leaves with the flue gas while the bed and walls are cold.

Why count refractory?

Cyclones and loop seals carry large refractory masses that must be heated slowly.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.