FireCADCalc

Minimum Bubbling Velocity and Maximum Stable Bubble

Minimum bubbling velocity of Group A powders (Abrahamsen and Geldart) and the maximum stable bubble size from the terminal velocity of 2.7 × mean size.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: FCC 60 µm, 10 % finesSand 300 µm (Group B)

Measured, or from the minimum fluidisation velocity calculator for the same particle and gas. A note compares it with Wen and Yu.

Results

For Group B and D solids (most boiler beds) bubbles form at U_mf, so U_mb = U_mf: the ratio is shown, but U_mb is never taken below U_mf.

Ratio U_mb/U_mf0.55452
Minimum bubbling velocity0.050000m/s
Maximum stable bubble size1.4867m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: FCC 60 µm, 10 % fines. The inputs, in the units selected above:

InputValue
Mean particle diameter (surface-volume)0.060000 mm
Particle density1,500.0 kg/m³
Gas density1.2000 kg/m³
Gas viscosity0.018000 cP
Mass fraction finer than 45 µm10.000 %
Minimum fluidisation velocity0.002000 m/s
Terminal velocity of particles 2.7 × mean size0.50000 m/s

Applying the formula below gives:

ResultValue
Ratio U_mb/U_mf2.5501
Minimum bubbling velocity0.005100 m/s
Maximum stable bubble size0.050986 m

Open this example in the calculator and change any input.

Formula

\(\frac{U_{mb}}{U_{mf}} = \frac{2300\mu^{0.523}\rho_g^{0.126}e^{0.716F}}{d_p^{0.8}g^{0.934}(\rho_p - \rho_g)^{0.934}}, \quad U_{mb} = \max\left(\frac{U_{mb}}{U_{mf}}, 1\right) U_{mf}, \quad D_{b,max} = \frac{2U_t^{*2}}{g}\)

Variables

Symbol Meaning SI unit
\(d_p\) Mean particle diameter (surface-volume) m
\(\rho_p\) Particle density kg/m³
\(\rho_g\) Gas density kg/m³
\(\mu\) Gas viscosity Pa·s
\(F\) Mass fraction finer than 45 µm -
\(U_{mf}\) Minimum fluidisation velocity m/s
\(U_t^*\) Terminal velocity of particles 2.7 × mean size m/s
\(U_{mb}/U_{mf}\) Ratio U_mb/U_mf -
\(U_{mb}\) Minimum bubbling velocity m/s
\(D_{b,max}\) Maximum stable bubble size m
\(g\) standard gravity, 9.80665 m/s²

Method and standards

Basu's Eqs. (2.4) and (2.5). U_mf is your input; a note compares it with the Wen and Yu (1966) value for the same particle and gas.

Where it is used

  • Bed material checks.
  • Pilot plant interpretation.

Common mistakes

  • Using for Group B solids (ratio below 1).

Assumptions and limits

  • SI units throughout.
  • The Abrahamsen and Geldart ratio applies to Group A powders; for Group B and D solids the ratio comes out below 1 and U_mb is taken equal to U_mf. The Geldart group is not checked.
  • U_mb is only as good as the U_mf entered.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2
  • Eqs. (2.4) (Abrahamsen and Geldart 1980) and (2.5) (Grace 1982)

Questions and answers

Why does only Group A have U_mb > U_mf?

Fine, light powders expand smoothly before bubbles form; coarser solids bubble as soon as they fluidise.

What does fines fraction do?

Fines below 45 µm widen the smooth-expansion range (the exp(0.716F) term).

How big can bubbles get?

Until their rise velocity matches the terminal velocity of 2.7 × mean-size particles.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.