Limestone Calcination: Equilibrium CO₂ Pressure and Temperature

Equilibrium CO₂ pressure over CaCO₃ at a bed temperature, and the lowest temperature for calcination at a CO₂ partial pressure (Basu Eq. 5.7).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 850 °C bed, 15 kPa CO2PFBC 12 bar, 180 kPa CO2 at 860 °C

Results

Limestone does not calcine at this temperature: the equilibrium CO₂ pressure is below the partial pressure (calcination needs at least 944 °C).

Pressurised beds and oxy-fuel firing raise CO₂ partial pressure; limestone then reacts uncalcined (direct sulfation).

Equilibrium CO₂ pressure at T56.172kPa
Equilibrium calcination temperature at p_CO₂943.98°C
Driving ratio (> 1: calcines)0.31207

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 850 °C bed, 15 kPa CO2. The inputs, in the units selected above:

InputValue
Bed temperature850.00 °C
CO₂ partial pressure in the furnace15.000 kPa

Applying the formula below gives:

ResultValue
Equilibrium CO₂ pressure at T48.335 kPa
Equilibrium calcination temperature at p_CO₂777.78 °C
Driving ratio (> 1: calcines)3.2223

Open this example in the calculator and change any input.

Formula

\(P_e = 1.2\times10^7\exp\left(-\frac{E}{RT}\right)\ \text{bar}, \quad T_e = \frac{-E}{R\ln(p_{CO_2}/1.2\times10^7)}\)

Variables

Symbol Meaning SI unit
\(T\) Bed temperature K
\(p_{CO_2}\) CO₂ partial pressure in the furnace Pa
\(P_e\) Equilibrium CO₂ pressure at T Pa
\(T_e\) Equilibrium calcination temperature at p_CO₂ K
\(P_e/p_{CO_2}\) Driving ratio (> 1: calcines) -

Method and standards

Basu's Eq. (5.7), with E = 159 000 kJ/kmol and R = 8.314 kJ/(kmol·K) as given with it; the pressure in bar is converted to pascals. A note says whether the limestone calcines (ratio above 1).

Where it is used

  • Sorbent behaviour checks.
  • Kiln and calciner checks.

Common mistakes

  • Using total pressure instead of CO₂ partial pressure.

Assumptions and limits

  • Equilibrium only; kinetics ignored.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 5
  • Eq. (5.7) (Stanton 1983): P_e = 1.2 × 10⁷ exp(−E/RT) bar
  • E = 159 000 kJ/kmol

Questions and answers

At what temperature does limestone calcine in flue gas?

With about 15 % CO₂ at 1 atm, above roughly 780 °C.

Why does it matter for sulphur capture?

Calcined CaO is porous and reactive; sulfation peaks near 850 °C.

What about pressurised beds?

At 10–15 bar the CO₂ partial pressure stops calcination at bed temperature.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.