FireCADCalc

CFB Furnace Voidage Profile and Solids Inventory

Exit voidage, mean upper-furnace voidage and solids inventory of a CFB furnace from dense and dilute voidages and the decay constant (Basu Eqs. 2.17–2.20).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 50 m2, 30 m furnaceBasu-style 10 m2, 20 m, a 0.3

Results

Mean upper voidage is the exact average of the exponential profile between h_i and H. The decay constant is per metre of height in every unit system.

The mean suspension density above h_i is above about 30 kg/m³, the top of the usual upper-furnace range: check the decay constant and the voidages.

Voidage at the furnace exit98.915%
Mean voidage above h_i96.272%
Solids inventory27.096t
Mean suspension density above h_i93.209kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 m2, 30 m furnace. The inputs, in the units selected above:

InputValue
Furnace cross-section50.000 m²
Furnace height30.000 m
Height of the inflexion (secondary air level)5.0000 m
Dense-bed voidage below h_i85.000 %
Dilute asymptotic voidage99.500 %
Decay constant0.50000 1/m
Particle density2,500.0 kg/m³

Applying the formula below gives:

ResultValue
Voidage at the furnace exit99.500 %
Mean voidage above h_i98.340 %
Solids inventory145.62 t
Mean suspension density above h_i41.500 kg/m³

Open this example in the calculator and change any input.

Formula

\(\varepsilon_e = \varepsilon_d - (\varepsilon_d - \varepsilon_a)e^{-a(H - h_i)}, \quad \bar\varepsilon_s = \varepsilon_d - \frac{(\varepsilon_d - \varepsilon_a)(1 - e^{-a(H - h_i)})}{a(H - h_i)}\)

\(W = A\rho_p[h_i(1 - \varepsilon_a) + (H - h_i)(1 - \bar\varepsilon_s)], \quad \rho_{susp} = \rho_p(1 - \bar\varepsilon_s)\)

Variables

Symbol Meaning SI unit
\(A\) Furnace cross-section m²
\(H\) Furnace height m
\(h_i\) Height of the inflexion (secondary air level) m
\(\varepsilon_a\) Dense-bed voidage below h_i -
\(\varepsilon_d\) Dilute asymptotic voidage -
\(a\) Decay constant, per metre of height 1/m
\(\rho_p\) Particle density kg/m³
\(\varepsilon_e\) Voidage at the furnace exit -
\(\varepsilon_s\) Mean voidage above h_i -
\(W\) Solids inventory kg
\(\rho_{susp}\) Mean suspension density above h_i kg/m³

Method and standards

Basu's exponential voidage model, averaged analytically.

Where it is used

  • CFB furnace design.
  • Fan head estimates.

Common mistakes

  • Using total height for the dense bed.
  • Mixing per-metre and per-mm decay constants.

Assumptions and limits

  • Uniform cross-section.
  • The decay constant is entered per metre even when heights are shown in feet; convert a per-foot value by multiplying by 3.281.
  • A note appears when the mean suspension density above \(h_i\) exceeds about 30 kg/m³.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2
  • Eqs. (2.17) to (2.20) (exponential decay of voidage above the inflexion)

Questions and answers

What is the decay constant?

How fast solids concentration falls with height above the dense bed; it depends on velocity and particle size (0.2–1 per m in boilers).

Why does inventory matter?

It sets bed pressure drop, fan head and the heat transfer to the walls.

Where is the inflexion?

Basu takes it at the secondary air level for a first approximation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.