Worked example
Example: 50 m2, 30 m furnace. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Furnace cross-section | 50.000 m² |
| Furnace height | 30.000 m |
| Height of the inflexion (secondary air level) | 5.0000 m |
| Dense-bed voidage below h_i | 85.000 % |
| Dilute asymptotic voidage | 99.500 % |
| Decay constant | 0.50000 1/m |
| Particle density | 2,500.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Voidage at the furnace exit | 99.500 % |
| Mean voidage above h_i | 98.340 % |
| Solids inventory | 145.62 t |
| Mean suspension density above h_i | 41.500 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(\varepsilon_e = \varepsilon_d - (\varepsilon_d - \varepsilon_a)e^{-a(H - h_i)}, \quad \bar\varepsilon_s = \varepsilon_d - \frac{(\varepsilon_d - \varepsilon_a)(1 - e^{-a(H - h_i)})}{a(H - h_i)}\)
\(W = A\rho_p[h_i(1 - \varepsilon_a) + (H - h_i)(1 - \bar\varepsilon_s)], \quad \rho_{susp} = \rho_p(1 - \bar\varepsilon_s)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Furnace cross-section | m² |
| \(H\) | Furnace height | m |
| \(h_i\) | Height of the inflexion (secondary air level) | m |
| \(\varepsilon_a\) | Dense-bed voidage below h_i | - |
| \(\varepsilon_d\) | Dilute asymptotic voidage | - |
| \(a\) | Decay constant, per metre of height | 1/m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\varepsilon_e\) | Voidage at the furnace exit | - |
| \(\varepsilon_s\) | Mean voidage above h_i | - |
| \(W\) | Solids inventory | kg |
| \(\rho_{susp}\) | Mean suspension density above h_i | kg/m³ |
Method and standards
Basu's exponential voidage model, averaged analytically.
Where it is used
- CFB furnace design.
- Fan head estimates.
Common mistakes
- Using total height for the dense bed.
- Mixing per-metre and per-mm decay constants.
Assumptions and limits
- Uniform cross-section.
- The decay constant is entered per metre even when heights are shown in feet; convert a per-foot value by multiplying by 3.281.
- A note appears when the mean suspension density above \(h_i\) exceeds about 30 kg/m³.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 2
- Eqs. (2.17) to (2.20) (exponential decay of voidage above the inflexion)
Questions and answers
What is the decay constant?
How fast solids concentration falls with height above the dense bed; it depends on velocity and particle size (0.2–1 per m in boilers).
Why does inventory matter?
It sets bed pressure drop, fan head and the heat transfer to the walls.
Where is the inflexion?
Basu takes it at the secondary air level for a first approximation.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.