Worked example
Example: 30 m² riser, 10 kg/(m²·s), 20 t/h fuel, solids cool 50 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Riser (furnace) cross-section | 30.000 m² |
| Net solids flux up the riser | 10.000 kg/(m²·s) |
| Fuel firing rate | 20.000 t/h |
| Specific heat of the solids | 0.83736 kJ/(kg·K) |
| Solids temperature leaving the furnace | 870.00 °C |
| Solids temperature returning to the furnace | 820.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Solids circulation rate | 1,080.0 t/h |
| Circulation ratio (solids per kg fuel) | 54.000 kg/kg |
| Heat given up by the circulating solids | 12,560 kW |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = G_s A_r\)
\(\dot m_s / \dot m_f\)
\(Q_s = \dot m_s c_s (T_1 - T_2)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A_r\) | riser cross-section | m² |
| \(G_s\) | net solids flux up the riser | kg/(m²·s) |
| \(\dot m_f\) | fuel firing rate | kg/s |
| \(c_s\) | specific heat of the solids | J/(kg·K) |
| \(T_1\) | solids temperature leaving the furnace | K |
| \(T_2\) | solids temperature returning | K |
| \(\dot m_s\) | solids circulation rate | kg/s |
| \(\dot m_s / \dot m_f\) | circulation ratio | kg/kg |
| \(Q_s\) | heat given up by the solids | W |
Method and standards
The circulation rate is the net upward solids flux times the riser cross-section; the ratio to fuel is the usual design figure. The heat the solids give up between leaving the furnace and returning (in an external heat exchanger, or none) is circulation rate times specific heat times temperature drop. Default solids specific heat is FireCAD's ash value, 0.2 Btu/(lb·°F).
Where it is used
- Checking a CFBC's circulation against the design.
- Estimating external heat exchanger duty.
- Explaining furnace temperature profiles.
Common mistakes
- Using the gross upward flux instead of the net flux (part of the solids fall back down the walls).
- Mixing kg/(m²·s) and t/(m²·h).
- Using the bed area of the lower furnace instead of the riser cross-section.
Assumptions and limits
- Net solids flux is an input, from measurement or design.
- Mean specific heat of the solids.
- Steady circulation.
References
- Mass and heat balance on the solids loop
Questions and answers
What is a typical CFBC circulation ratio?
Tens of kg of solids per kg of fuel. A 30 m² riser at 10 kg/(m²·s) circulates 300 kg/s, 54 times the 20 t/h fuel rate.
How is the solids flux found on a running boiler?
From the pressure profile up the riser, from a loop-seal measurement, or from a heat balance across an external heat exchanger.
Why does circulation matter?
The circulating solids carry heat to the walls and the external heat exchanger and keep the furnace temperature even; too little circulation lets the bottom run hot.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.