CFB Wall Layer (Annulus) Thickness

Thickness of the down-flowing solids layer on CFB furnace walls from equivalent diameter and voidage, or from height alone (Basu Eqs. 2.22–2.23).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 9 m furnace, ε 0.99 at 20 m of 30 mLow in the furnace

Results

Large CFB boilers show wall layers of 70–350 mm; the layer carries most of the heat to the water walls.

Layer thickness from voidage (Eq. 2.22)1,723.2mm
Layer thickness from height (Eq. 2.23)342.73mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 9 m furnace, ε 0.99 at 20 m of 30 m. The inputs, in the units selected above:

InputValue
Equivalent (hydraulic) furnace diameter, 4A/P9.0000 m
Cross-section average voidage at the height99.000 %
Furnace height30.000 m
Height of interest above the distributor20.000 m

Applying the formula below gives:

ResultValue
Layer thickness from voidage (Eq. 2.22)478.80 mm
Layer thickness from height (Eq. 2.23)161.19 mm

Open this example in the calculator and change any input.

Formula

\(\delta = D_{eq}[0.008 + 4.52(1 - \varepsilon_{av}(z))], \quad \delta = 0.00385H\exp\left(1 - \frac{z}{H}\right)\)

Variables

Symbol Meaning SI unit
\(D_{eq}\) Equivalent (hydraulic) furnace diameter, 4 × cross-section ÷ perimeter m
\(\varepsilon_{av}(z)\) Cross-section average voidage at the height -
\(H\) Furnace height m
\(z\) Height of interest, measured up from the distributor (grid) m
\(\delta_1\) Layer thickness from voidage (Eq. 2.22) m
\(\delta_2\) Layer thickness from height (Eq. 2.23) m

Method and standards

Basu's Eqs. (2.22)–(2.23).

Where it is used

  • Wall heat transfer and erosion studies.

Common mistakes

  • Using in laboratory-scale risers (layers are millimetres there).

Assumptions and limits

  • Large boilers.
  • The two equations are separate fits and can differ by a factor of about three at the same height; Eq. 2.22 reflects the local voidage you enter, Eq. 2.23 only the height. Prefer Eq. 2.22 when the voidage is known.
  • Eq. 2.22 is outside its range when it gives a layer thicker than the furnace radius (voidage below about 0.9); a warning is shown.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2
  • Eqs. (2.22) and (2.23) (Johansson et al. 2005, 2007)

Questions and answers

What is the wall layer?

A dense layer of solids sliding down the walls around a dilute upward core.

Which equation should I use?

Eq. 2.22 when the local voidage is known; Eq. 2.23 when it is not.

Why does it thin with height?

Fewer solids are present higher in the furnace.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.