Worked example
Example: 9 m furnace, ε 0.99 at 20 m of 30 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Equivalent (hydraulic) furnace diameter, 4A/P | 9.0000 m |
| Cross-section average voidage at the height | 99.000 % |
| Furnace height | 30.000 m |
| Height of interest above the distributor | 20.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Layer thickness from voidage (Eq. 2.22) | 478.80 mm |
| Layer thickness from height (Eq. 2.23) | 161.19 mm |
Open this example in the calculator and change any input.
Formula
\(\delta = D_{eq}[0.008 + 4.52(1 - \varepsilon_{av}(z))], \quad \delta = 0.00385H\exp\left(1 - \frac{z}{H}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D_{eq}\) | Equivalent (hydraulic) furnace diameter, 4 × cross-section ÷ perimeter | m |
| \(\varepsilon_{av}(z)\) | Cross-section average voidage at the height | - |
| \(H\) | Furnace height | m |
| \(z\) | Height of interest, measured up from the distributor (grid) | m |
| \(\delta_1\) | Layer thickness from voidage (Eq. 2.22) | m |
| \(\delta_2\) | Layer thickness from height (Eq. 2.23) | m |
Method and standards
Basu's Eqs. (2.22)–(2.23).
Where it is used
- Wall heat transfer and erosion studies.
Common mistakes
- Using in laboratory-scale risers (layers are millimetres there).
Assumptions and limits
- Large boilers.
- The two equations are separate fits and can differ by a factor of about three at the same height; Eq. 2.22 reflects the local voidage you enter, Eq. 2.23 only the height. Prefer Eq. 2.22 when the voidage is known.
- Eq. 2.22 is outside its range when it gives a layer thicker than the furnace radius (voidage below about 0.9); a warning is shown.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 2
- Eqs. (2.22) and (2.23) (Johansson et al. 2005, 2007)
Questions and answers
What is the wall layer?
A dense layer of solids sliding down the walls around a dilute upward core.
Which equation should I use?
Eq. 2.22 when the local voidage is known; Eq. 2.23 when it is not.
Why does it thin with height?
Fewer solids are present higher in the furnace.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.