CFB Gas–Solid Slip Velocity and Suspension Density

Gas–solid slip velocity in a fast bed from superficial gas velocity, solids flux and voidage (Basu Eq. 2.25), with the suspension density and solids velocity.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 5.5 m/s, 20 kg/m2 s, ε 0.98Dense bottom ε 0.9

Results

In the core the slip is of the order of the particle terminal velocity; near the wall solids may fall against the gas.

Interstitial gas velocity5.6122m/s
Solids velocity0.40000m/s
Slip velocity5.2122m/s
Suspension density50.000kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5.5 m/s, 20 kg/m2 s, ε 0.98. The inputs, in the units selected above:

InputValue
Superficial gas velocity5.5000 m/s
Solids flux20.000 kg/(m²·s)
Local voidage98.000 %
Particle density2,500.0 kg/m³

Applying the formula below gives:

ResultValue
Interstitial gas velocity5.6122 m/s
Solids velocity0.40000 m/s
Slip velocity5.2122 m/s
Suspension density50.000 kg/m³

Open this example in the calculator and change any input.

Formula

\(U_{slip} = \frac{U}{\varepsilon} - \frac{G_s}{(1 - \varepsilon)\rho_p}, \quad \rho_{susp} = \rho_p(1 - \varepsilon)\)

Variables

Symbol Meaning SI unit
\(U\) Superficial gas velocity m/s
\(G_s\) Solids flux kg/(m²·s)
\(\varepsilon\) Local voidage -
\(\rho_p\) Particle density kg/m³
\(U/\varepsilon\) Interstitial gas velocity m/s
\(U_s\) Solids velocity m/s
\(U_{slip}\) Slip velocity m/s
\(\rho_{susp}\) Suspension density kg/m³

Method and standards

Basu's Eq. (2.25).

Where it is used

  • CFB riser analysis.

Common mistakes

  • Using superficial instead of interstitial velocity.
  • Taking solids flux at the wrong height.

Assumptions and limits

  • Cross-section averages.
  • A warning is given when the solids velocity exceeds U/ε (negative slip): the inputs are inconsistent with up-flow.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2
  • Eq. (2.25)

Questions and answers

Why is slip high in fast beds?

Particles form clusters that fall back through the gas, so mean slip exceeds a single particle's terminal velocity.

What is suspension density?

Solids mass per unit furnace volume, ρ_p(1 − ε); 5–30 kg/m³ in the upper furnace.

Why does it matter?

Heat transfer to the walls rises with suspension density.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.