Worked example
Example: 15 kg/m3 at 850 °C, constant 5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Average suspension density | 15.000 kg/m³ |
| Bed temperature | 850.00 °C |
| Constant (5 general, or calibrated) | 5.0000 - |
| Water wall area (projected) | 2,000.0 m² |
| Wall (fluid) temperature | 300.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat transfer coefficient | 253.16 W/(m²·K) |
| Heat absorbed by the walls | 278.48 MW |
Open this example in the calculator and change any input.
Formula
\(h = C\,\rho_{avg}^{0.391}T_b^{0.408}, \quad Q = hA_w(T_b - T_w)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho_{avg}\) | Average suspension density | kg/m³ |
| \(T_b\) | Bed temperature | K |
| \(C\) | Constant (5 general, or calibrated) | - |
| \(A_w\) | Water wall area, projected (flat) area of the membrane wall | m² |
| \(T_w\) | Wall (fluid) temperature | K |
| \(h\) | Heat transfer coefficient | W/(m²·K) |
| \(Q\) | Heat absorbed by the walls | W |
Method and standards
Dutta–Basu empirical correlation.
Where it is used
- CFB furnace surface sizing.
Common mistakes
- Using T in °C.
- Applying to bubbling beds.
Assumptions and limits
- Commercial CFB boilers; gross correlation. The source gives no explicit validity range; values above the 100–250 W/m²·K typical of the upper furnace occur in the denser lower furnace, so check against a measured boiler (calibrate \(C\)).
- The area must be on the basis the coefficient was derived on (projected membrane-wall area); using the full tube surface overstates the heat by roughly the ratio of tube to projected area, about 1.4.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 3
- Eq. (3.28) (Dutta and Basu 2002) and its worked example
Questions and answers
What values are typical?
100–250 W/m²·K in the upper furnace, higher near the bottom where the bed is denser.
Why suspension density?
Clusters sliding down the walls carry heat; more solids mean more contact.
Is temperature in kelvin?
Yes: T_b in K in the correlation.