CFB Furnace Wall Heat Transfer Coefficient (Dutta and Basu)

Heat transfer coefficient to CFB furnace water walls from average suspension density and bed temperature (Dutta and Basu), with the heat the walls absorb.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 15 kg/m3 at 850 °C, constant 5Basu's calibrated constant 4.4, 30 kg/m3

Results

Basu calibrates the constant from a measured boiler: 224 W/m²·K at 15 kg/m³ and 850 °C gives 4.4.

Heat transfer coefficient253.16W/(m²·K)
Heat absorbed by the walls278.48MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 kg/m3 at 850 °C, constant 5. The inputs, in the units selected above:

InputValue
Average suspension density15.000 kg/m³
Bed temperature850.00 °C
Constant (5 general, or calibrated)5.0000 -
Water wall area (projected)2,000.0 m²
Wall (fluid) temperature300.00 °C

Applying the formula below gives:

ResultValue
Heat transfer coefficient253.16 W/(m²·K)
Heat absorbed by the walls278.48 MW

Open this example in the calculator and change any input.

Formula

\(h = C\,\rho_{avg}^{0.391}T_b^{0.408}, \quad Q = hA_w(T_b - T_w)\)

Variables

Symbol Meaning SI unit
\(\rho_{avg}\) Average suspension density kg/m³
\(T_b\) Bed temperature K
\(C\) Constant (5 general, or calibrated) -
\(A_w\) Water wall area, projected (flat) area of the membrane wall m²
\(T_w\) Wall (fluid) temperature K
\(h\) Heat transfer coefficient W/(m²·K)
\(Q\) Heat absorbed by the walls W

Method and standards

Dutta–Basu empirical correlation.

Where it is used

  • CFB furnace surface sizing.

Common mistakes

  • Using T in °C.
  • Applying to bubbling beds.

Assumptions and limits

  • Commercial CFB boilers; gross correlation. The source gives no explicit validity range; values above the 100–250 W/m²·K typical of the upper furnace occur in the denser lower furnace, so check against a measured boiler (calibrate \(C\)).
  • The area must be on the basis the coefficient was derived on (projected membrane-wall area); using the full tube surface overstates the heat by roughly the ratio of tube to projected area, about 1.4.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 3
  • Eq. (3.28) (Dutta and Basu 2002) and its worked example

Questions and answers

What values are typical?

100–250 W/m²·K in the upper furnace, higher near the bottom where the bed is denser.

Why suspension density?

Clusters sliding down the walls carry heat; more solids mean more contact.

Is temperature in kelvin?

Yes: T_b in K in the correlation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.