Worked example
Example: 8 kPa over 30 m2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bed pressure drop (excluding the distributor) | 8.0000 kPa |
| Bed cross-section | 30.000 m² |
| Particle density | 2,500.0 kg/m³ |
| Bed voidage | 50.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bed inventory | 24.473 t |
| Bed height at this voidage | 0.65262 m |
Open this example in the calculator and change any input.
Formula
\(W = \frac{\Delta p_bA}{g}, \quad H_b = \frac{W}{A\rho_p(1 - \varepsilon)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\Delta p_b\) | Bed pressure drop (excluding the distributor) | Pa |
| \(A\) | Bed cross-section | m² |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\varepsilon\) | Bed voidage | - |
| \(W\) | Bed inventory | kg |
| \(H_b\) | Bed height at this voidage | m |
| \(g\) | standard gravity, 9.80665 | m/s² |
Method and standards
Force balance on a fluidised bed.
Where it is used
- Bed level control.
- Start-up inventory.
Common mistakes
- Including distributor Δp.
- Using bulk density as particle density.
Assumptions and limits
- Fully fluidised bed; the pressure drop is the weight of the solids between the taps.
- In a CFB the measured lower-furnace Δp also includes acceleration and wall friction, and part of the inventory sits in the dilute upper furnace and the loop; the result is the solids between the taps only, not the total loop inventory.
References
- Basu
- Circulating Fluidized Bed Boilers: Design
- Operation and Maintenance (Springer, 2015)
- ch. 2 and 11: a fluidised bed's pressure drop equals the weight of bed solids per unit area
Questions and answers
Why does Δp give the inventory?
Once fluidised, the gas supports the whole weight of the bed.
What Δp is usual?
Bubbling beds 6–12 kPa; CFB lower furnaces similar, plus the dilute upper furnace.
Does it include the distributor?
No; subtract the distributor's pressure drop first.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.