Bed Inventory and Height from Bed Pressure Drop

Mass of bed material from the measured bed pressure drop and cross-section (Δp = W g / A), with the expanded or settled bed height for a voidage.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: 8 kPa over 30 m2Bubbling bed 10 kPa, 12 m2

Results

Operators drain bed material to keep the pressure drop at its set point: it is the inventory measurement.

Bed inventory12.237t
Bed height at this voidage0.74161m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 8 kPa over 30 m2. The inputs, in the units selected above:

InputValue
Bed pressure drop (excluding the distributor)8.0000 kPa
Bed cross-section30.000 m²
Particle density2,500.0 kg/m³
Bed voidage50.000 %

Applying the formula below gives:

ResultValue
Bed inventory24.473 t
Bed height at this voidage0.65262 m

Open this example in the calculator and change any input.

Formula

\(W = \frac{\Delta p_bA}{g}, \quad H_b = \frac{W}{A\rho_p(1 - \varepsilon)}\)

Variables

Symbol Meaning SI unit
\(\Delta p_b\) Bed pressure drop (excluding the distributor) Pa
\(A\) Bed cross-section m²
\(\rho_p\) Particle density kg/m³
\(\varepsilon\) Bed voidage -
\(W\) Bed inventory kg
\(H_b\) Bed height at this voidage m
\(g\) standard gravity, 9.80665 m/s²

Method and standards

Force balance on a fluidised bed.

Where it is used

  • Bed level control.
  • Start-up inventory.

Common mistakes

  • Including distributor Δp.
  • Using bulk density as particle density.

Assumptions and limits

  • Fully fluidised bed; the pressure drop is the weight of the solids between the taps.
  • In a CFB the measured lower-furnace Δp also includes acceleration and wall friction, and part of the inventory sits in the dilute upper furnace and the loop; the result is the solids between the taps only, not the total loop inventory.

References

  • Basu
  • Circulating Fluidized Bed Boilers: Design
  • Operation and Maintenance (Springer, 2015)
  • ch. 2 and 11: a fluidised bed's pressure drop equals the weight of bed solids per unit area

Questions and answers

Why does Δp give the inventory?

Once fluidised, the gas supports the whole weight of the bed.

What Δp is usual?

Bubbling beds 6–12 kPa; CFB lower furnaces similar, plus the dilute upper furnace.

Does it include the distributor?

No; subtract the distributor's pressure drop first.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.