AFBC Bed Heat Balance and In-Bed Tube Duty

Heat the in-bed tubes of a bubbling fluidised bed boiler must remove to hold the bed temperature, and the tube area for it, from an energy balance on the bed.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileBoiler

Inputs

Examples: Coal AFBC 10 t/h, NCV 14 MJ/kg, bed 850 °C, tubes at 255 °CRice husk 6 t/h, NCV 12.5 MJ/kg, bed 800 °C, 75 % in bedLignite 15 t/h, NCV 11 MJ/kg, air preheated to 150 °C

The rest burns in the freeboard above the bed; from the boiler maker or a test.
Overall value including the tube-side film and wall, because it is applied to the bed-to-fluid temperature difference; from the boiler maker or a test on a similar bed.

Results

Radiation from the bed surface to the freeboard and the wall losses are not included; they lower the in-bed duty a little.

Heat released in the bed41,250kW
Heat carried up by the flue gas19,445kW
Heat in the bed ash drained366.35kW
Heat the in-bed tubes must take21,438kW
In-bed duty as a share of the fuel heat46.774%
In-bed tube surface needed149.92m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal AFBC 10 t/h, NCV 14 MJ/kg, bed 850 °C, tubes at 255 °C. The inputs, in the units selected above:

InputValue
Fuel firing rate10.000 t/h
Net calorific value, as fired14,000 kJ/kg
Share of the fuel's heat released in the bed85.000 %
Combustion air per kg fuel (with excess air)6.5000 kg/kg
Ash in fuel, as fired30.000 %
Mean specific heat of the flue gas, air to bed temperature1.1500 kJ/(kg·K)
Bed temperature to hold850.00 °C
Fluidising air and fuel temperature30.000 °C
Water or steam temperature in the in-bed tubes255.00 °C
Overall heat transfer coefficient, bed to tube contents250.00 W/(m²·K)

Applying the formula below gives:

ResultValue
Heat released in the bed33,056 kW
Heat carried up by the flue gas18,860 kW
Heat in the bed ash drained572.20 kW
Heat the in-bed tubes must take13,623 kW
In-bed duty as a share of the fuel heat35.031 %
In-bed tube surface needed91.586 m²

Open this example in the calculator and change any input.

Formula

\(Q_{rel} = \dot m_f\, NCV\, \beta\)

\(Q_g = \dot m_f (a + 1 - A)\, c_{p,g} (T_b - T_a)\)

\(Q_{ash} = \dot m_f A\, c_{ash} (T_b - T_a)\)

\(Q_t = Q_{rel} - Q_g - Q_{ash}, \quad A_t = \frac{Q_t}{U (T_b - T_w)}\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) fuel firing rate kg/s
\(NCV\) net calorific value, as fired J/kg
\(\beta\) share of the fuel heat released in the bed -
\(a\) combustion air per kg fuel kg/kg
\(A\) ash in fuel -
\(c_{p,g}\) mean specific heat of the flue gas J/(kg·K)
\(c_{ash}\) specific heat of ash, 0.2 Btu/(lb·°F) J/(kg·K)
\(T_b\) bed temperature K
\(T_a\) air and fuel temperature K
\(T_w\) water or steam temperature in the tubes K
\(U\) overall heat transfer coefficient, bed to tube contents (includes tube-side film and wall) W/(m²·K)
\(Q_{rel}\) heat released in the bed W
\(Q_g\) heat carried up by the gas W
\(Q_{ash}\) heat in the bed ash W
\(Q_t\) in-bed tube duty W
\(Q_f\) fuel heat input (NCV) W
\(Q_t / Q_f\) in-bed duty as a share of the fuel heat -
\(A_t\) in-bed tube surface m²

Method and standards

A steady energy balance on the bed: the heat released by the share of fuel burning in the bed (on NCV) equals the heat the gas carries up at bed temperature, the heat in the ash drained, and the duty of the in-bed tubes. The tube area follows from the bed-to-tube coefficient and the temperature difference between bed and tube contents. Ash specific heat is 0.2 Btu/(lb·°F), the value FireCAD uses for coal and biomass ash.

Where it is used

  • Sizing in-bed evaporator or superheater coils.
  • Checking why a bed runs too hot or too cold after a fuel change.
  • Estimating bed temperature control margin.

Common mistakes

  • Using GCV instead of NCV for the heat released.
  • Assuming all the fuel burns in the bed; volatile fuels burn largely in the freeboard.
  • Taking U from a different bed type or velocity.

Assumptions and limits

  • Steady state; radiation from the bed surface and wall losses not included.
  • All ash leaves at bed temperature, whether drained from the bed or carried out as fly ash; unburnt carbon in the ash is neglected.
  • All the fuel is taken to devolatilise in the bed, so the gas term uses the whole fuel mass heated to bed temperature, while only the share \(\beta\) of the heat is credited to the bed.
  • Gas specific heat is a mean value between air and bed temperatures.

References

  • Energy balance on the fluidised bed

Questions and answers

How much of the fuel's heat do the in-bed tubes take?

Typically a third to a half. In the example, 10 t/h of coal at 14 MJ/kg with 85 % burning in the bed at 850 °C needs about 13.6 MW, or 35 % of the fuel heat, taken by in-bed tubes.

What if the balance gives no heat for the tubes?

Then the gas and ash carry away all the heat released, so the bed cannot reach that temperature: less of the fuel is burning in the bed, or the fuel is too wet or too lean.

Why use NCV here?

The water from the fuel leaves the bed as vapour, so its latent heat is never released in the bed; the gas specific heat then covers only sensible heat.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.