Worked example
Example: Coal AFBC 10 t/h, NCV 14 MJ/kg, bed 850 °C, tubes at 255 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel firing rate | 10.000 t/h |
| Net calorific value, as fired | 14,000 kJ/kg |
| Share of the fuel's heat released in the bed | 85.000 % |
| Combustion air per kg fuel (with excess air) | 6.5000 kg/kg |
| Ash in fuel, as fired | 30.000 % |
| Mean specific heat of the flue gas, air to bed temperature | 1.1500 kJ/(kg·K) |
| Bed temperature to hold | 850.00 °C |
| Fluidising air and fuel temperature | 30.000 °C |
| Water or steam temperature in the in-bed tubes | 255.00 °C |
| Overall heat transfer coefficient, bed to tube contents | 250.00 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat released in the bed | 33,056 kW |
| Heat carried up by the flue gas | 18,860 kW |
| Heat in the bed ash drained | 572.20 kW |
| Heat the in-bed tubes must take | 13,623 kW |
| In-bed duty as a share of the fuel heat | 35.031 % |
| In-bed tube surface needed | 91.586 m² |
Open this example in the calculator and change any input.
Formula
\(Q_{rel} = \dot m_f\, NCV\, \beta\)
\(Q_g = \dot m_f (a + 1 - A)\, c_{p,g} (T_b - T_a)\)
\(Q_{ash} = \dot m_f A\, c_{ash} (T_b - T_a)\)
\(Q_t = Q_{rel} - Q_g - Q_{ash}, \quad A_t = \frac{Q_t}{U (T_b - T_w)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_f\) | fuel firing rate | kg/s |
| \(NCV\) | net calorific value, as fired | J/kg |
| \(\beta\) | share of the fuel heat released in the bed | - |
| \(a\) | combustion air per kg fuel | kg/kg |
| \(A\) | ash in fuel | - |
| \(c_{p,g}\) | mean specific heat of the flue gas | J/(kg·K) |
| \(c_{ash}\) | specific heat of ash, 0.2 Btu/(lb·°F) | J/(kg·K) |
| \(T_b\) | bed temperature | K |
| \(T_a\) | air and fuel temperature | K |
| \(T_w\) | water or steam temperature in the tubes | K |
| \(U\) | overall heat transfer coefficient, bed to tube contents (includes tube-side film and wall) | W/(m²·K) |
| \(Q_{rel}\) | heat released in the bed | W |
| \(Q_g\) | heat carried up by the gas | W |
| \(Q_{ash}\) | heat in the bed ash | W |
| \(Q_t\) | in-bed tube duty | W |
| \(Q_f\) | fuel heat input (NCV) | W |
| \(Q_t / Q_f\) | in-bed duty as a share of the fuel heat | - |
| \(A_t\) | in-bed tube surface | m² |
Method and standards
A steady energy balance on the bed: the heat released by the share of fuel burning in the bed (on NCV) equals the heat the gas carries up at bed temperature, the heat in the ash drained, and the duty of the in-bed tubes. The tube area follows from the bed-to-tube coefficient and the temperature difference between bed and tube contents. Ash specific heat is 0.2 Btu/(lb·°F), the value FireCAD uses for coal and biomass ash.
Where it is used
- Sizing in-bed evaporator or superheater coils.
- Checking why a bed runs too hot or too cold after a fuel change.
- Estimating bed temperature control margin.
Common mistakes
- Using GCV instead of NCV for the heat released.
- Assuming all the fuel burns in the bed; volatile fuels burn largely in the freeboard.
- Taking U from a different bed type or velocity.
Assumptions and limits
- Steady state; radiation from the bed surface and wall losses not included.
- All ash leaves at bed temperature, whether drained from the bed or carried out as fly ash; unburnt carbon in the ash is neglected.
- All the fuel is taken to devolatilise in the bed, so the gas term uses the whole fuel mass heated to bed temperature, while only the share \(\beta\) of the heat is credited to the bed.
- Gas specific heat is a mean value between air and bed temperatures.
References
- Energy balance on the fluidised bed
Questions and answers
How much of the fuel's heat do the in-bed tubes take?
Typically a third to a half. In the example, 10 t/h of coal at 14 MJ/kg with 85 % burning in the bed at 850 °C needs about 13.6 MW, or 35 % of the fuel heat, taken by in-bed tubes.
What if the balance gives no heat for the tubes?
Then the gas and ash carry away all the heat released, so the bed cannot reach that temperature: less of the fuel is burning in the bed, or the fuel is too wet or too lean.
Why use NCV here?
The water from the fuel leaves the bed as vapour, so its latent heat is never released in the bed; the gas specific heat then covers only sensible heat.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.