Worked example
Example: Air 20 kg/s, bed 850 °C, 2.0 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluidising air flow | 72,000 kg/h |
| Bed temperature | 850.00 °C |
| Pressure above the bed (absolute) | 1.0132 bar |
| Superficial velocity at bed temperature | 2.0000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Bed plan area | 31.818 m² |
| Gas volume flow at bed temperature | 229,086 m³/h |
| Side of an equivalent square bed | 5.6407 m |
Open this example in the calculator and change any input.
Formula
\(\dot V = \frac{\dot m_a}{\rho(T_b, p)} \qquad A_b = \frac{\dot V}{u_0} \qquad s = \sqrt{A_b}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_a\) | fluidising air flow | kg/s |
| \(T_b\) | bed temperature | K |
| \(p\) | pressure above the bed | Pa |
| \(u_0\) | superficial velocity | m/s |
| \(A_b\) | bed plan area | m² |
| \(\dot V\) | gas volume at bed temperature | m³/s |
| \(s\) | side of an equivalent square | m |
| \(\rho\) | air density at bed conditions | kg/m³ |
Method and standards
Air density at bed temperature by the ideal-gas law (dry air molar mass); volume flow over superficial velocity.
Where it is used
- First sizing of AFBC boilers.
- Checking an existing bed for a higher load.
- Explaining elutriation and erosion problems.
Common mistakes
- Using ambient air density.
- Ignoring the gas added by combustion and moisture.
- Choosing velocity without checking U_mf of the coarsest particles.
Assumptions and limits
- Air as the gas; uniform distribution across the bed. Combustion products and fuel moisture raise the gas volume a few per cent for dry coal and 10 % or more for wet biomass; allow for it in the area.
- The velocity is not checked against the bed material's minimum fluidisation or terminal velocity; a warning appears outside the usual 1–3 m/s of bubbling beds.
References
- Continuity with the ideal-gas law for air
Questions and answers
How big a bed does an AFBC boiler need?
Gas volume at bed temperature divided by the superficial velocity. 20 kg/s of air at 850 °C is 63.6 m³/s; at 2.0 m/s the bed needs 31.8 m², a square of 5.6 m.
Why use the bed temperature?
The air expands about four times from ambient to 850 °C, so the velocity in the bed is set by the hot volume.
What velocity should I choose?
The boiler maker's design value: high enough to fluidise the coarse bed particles, low enough to limit elutriation of fines and erosion of in-bed tubes.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.