Condenser Air Removal: Vapour Load and Suction Volume

Air–vapour mixture mass and suction volume a condenser vacuum pump or ejector must remove for an air in-leakage, at suction pressure and offtake temperature.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: 30 kg/h air at 8 kPa(a), 4.2 K subcooled10 kg/h at 12 kPa(a), 3 K

Results

Dalton's law with the mixture saturated at the offtake temperature. Subcooling the air–vapour mixture in the air-cooling section cuts the vapour load sharply; the 4.2 K default is a FireCAD starting value; use the condenser maker's air-cooling section design.

Saturation temperature41.510°C
Mixture temperature37.310°C
Vapour partial pressure6.3888kPa
Vapour carried with the air73.982kg/h
Total mixture103.98kg/h
Suction volume1,659.3m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 kg/h air at 8 kPa(a), 4.2 K subcooled. The inputs, in the units selected above:

InputValue
Dry air in-leakage30.000 kg/h
Suction pressure (absolute)8.0000 kPa
Air-offtake subcooling below saturation4.2000 K

Applying the formula below gives:

ResultValue
Saturation temperature41.510 °C
Mixture temperature37.310 °C
Vapour partial pressure6.3888 kPa
Vapour carried with the air73.982 kg/h
Total mixture103.98 kg/h
Suction volume1,659.3 m³/h

Open this example in the calculator and change any input.

Formula

\(\dot m_v = \dot m_a\frac{p_v}{p - p_v}\frac{M_w}{M_a}, \quad \dot V = \frac{\dot m_aR_aT}{p - p_v}, \quad p_v = p_{sat}(T_s - \Delta T)\)

Variables

Symbol Meaning SI unit
\(\dot m_a\) Dry air in-leakage kg/s
\(p\) Suction pressure (absolute) Pa
\(\Delta T\) Air-offtake subcooling below saturation K
\(T_s\) Saturation temperature K
\(T\) Mixture temperature K
\(p_v\) Vapour partial pressure Pa
\(M_w\) molar mass of water, 18.015 kg/kmol
\(M_a\) molar mass of dry air, 28.96 kg/kmol
\(R_a\) gas constant of dry air, \(R/M_a\) = 287.06 J/(kg·K)
\(\dot m_v\) Vapour carried with the air kg/s
\(\dot m\) Total mixture kg/s
\(\dot V\) Suction volume m³/s

Method and standards

Dalton's law.

Where it is used

  • Vacuum pump and ejector checks.
  • Air in-leakage tests.

Common mistakes

  • Sizing on dry air alone.
  • Using the condenser saturation temperature at the offtake.

Assumptions and limits

  • Mixture saturated at the offtake temperature.
  • At zero subcooling the vapour load grows without bound, so at least 0.5 K is required. The 4.2 K default is a FireCAD starting value, not a code figure.

References

  • Dalton's law of partial pressures with IAPWS-IF97 saturation (definitions)

Questions and answers

Why is the vapour load so large?

At low pressure the air carries several times its own mass of water vapour: at 8 kPa and 37 °C, each kilogram of air brings about 2.5 kg of vapour.

Why subcool the mixture?

Cooling the offtake a few kelvin below saturation lowers the vapour pressure and so the vapour load and suction volume.

What do the defaults give?

30 kg/h of air at 8 kPa(a), 4.2 K subcooled: about 74 kg/h of vapour and roughly 1,660 m³/h of suction volume.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.