FireCADCalc

Surface Condenser Heat Load and Cooling Water Flow

Heat load of a steam surface condenser and the cooling water flow it needs, from exhaust steam flow and dryness, condenser pressure and cooling water temperatures.

Thermal power plantSugar mill and cogenerationChemical and fertiliserPulp and paperIAPWS-IF97 (water and steam)Steam turbineCondenser and cooling towerBoiler operation engineer (BOE) examinations

Inputs

Examples: 40 t/h at 0.1 bar(a), 90 % dry, CW 32 to 41 °C15 t/h at 0.12 bar(a), 92 % dry, 2 K subcooled, CW 30 to 40 °C400 t/h at 0.085 bar(a), 89 % dry, CW 33 to 42 °C

Results

Condenser heat load237.30MW
Cooling water flow2.2717e+07kg/h
Cooling water volume flow22,836m³/h
Saturation temperature in the condenser42.665°C
Exhaust steam enthalpy2,314.3kJ/kg
Condensate enthalpy178.68kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 t/h at 0.1 bar(a), 90 % dry, CW 32 to 41 °C. The inputs, in the units selected above:

InputValue
Exhaust steam flow to the condenser40,000 kg/h
Exhaust steam dryness fraction90.000 %
Condenser pressure (absolute)10.000 kPa
Condensate subcooling below saturation0 K
Cooling water inlet temperature32.000 °C
Cooling water outlet temperature41.000 °C
Cooling water pressure (absolute)3.0000 bar

Applying the formula below gives:

ResultValue
Condenser heat load23.921 MW
Cooling water flow2,289,974 kg/h
Cooling water volume flow2,301.2 m³/h
Saturation temperature in the condenser45.808 °C
Exhaust steam enthalpy2,344.7 kJ/kg
Condensate enthalpy191.81 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_s\,(h_{in} - h_c) \qquad h_{in} = h_f + x\,h_{fg} \ \text{at}\ p_c \qquad h_c = h(p_c,\ T_{sat} - \Delta T_{sub})\)

\(\dot m_{cw} = \frac{\dot Q}{h(T_{cw,2}) - h(T_{cw,1})} \qquad \dot V_{cw} = \frac{\dot m_{cw}}{\rho(T_{cw,1})} \quad \text{(water properties at } p_{cw}\text{)}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) exhaust steam flow kg/s
\(x\) exhaust steam dryness –
\(p_c\) condenser pressure, absolute Pa
\(\Delta T_{sub}\) condensate subcooling K
\(T_{cw,1}\) cooling water inlet temperature K
\(T_{cw,2}\) cooling water outlet temperature K
\(p_{cw}\) cooling water pressure, absolute Pa
\(\dot Q\) condenser heat load W
\(\dot m_{cw}\) cooling water mass flow kg/s
\(\dot V_{cw}\) cooling water volume flow m³/s
\(T_{sat}\) saturation temperature K
\(h_{in}\) exhaust steam enthalpy J/kg
\(h_c\) condensate enthalpy J/kg
\(h_f\), \(h_{fg}\) saturated liquid enthalpy and latent heat at \(p_c\) J/kg
\(\rho\) water density kg/m³

Method and standards

Energy balance of the condenser; steam, condensate and cooling water properties by FireCAD's IAPWS-IF97. Terms (TTD, ITD, heat load) as used in the HEI condenser standards.

Where it is used

  • Sizing condensers and cooling water pumps for captive and utility turbines.
  • Cooling tower sizing: the condenser load is most of the tower load.
  • Checking condenser performance against design.

Common mistakes

  • Assuming dry exhaust steam.
  • Forgetting other loads on the condenser: drains, gland steam, turbine bypass.
  • Using the cooling water outlet temperature from a probe close to the outlet water box, where it is not mixed.

Assumptions and limits

  • Exhaust wet or saturated at condenser pressure; condensate at saturation unless subcooling is entered; no air in the steam.
  • Only the turbine exhaust is counted. Heater drains, gland steam, turbine bypass and other flows dumped into the condenser add to the load; include them in the steam flow at their own enthalpy.

References

  • IAPWS R7-97(2012) IF97
  • HEI Standards for Steam Surface Condensers (terminology)

Questions and answers

How do I calculate condenser heat load?

Steam flow times the enthalpy it gives up. 40 t/h of 90 % dry exhaust at 0.1 bar(a) condensing to saturated water gives 23.9 MW; cooling water rising from 32 to 41 °C needs 636 kg/s, about 2300 m³/h.

Why does dryness matter?

Wet steam has already lost part of its latent heat. Assuming dry exhaust overstates the load by the moisture share, about 10 %.

What cooling water rise should I choose?

Usually 8–10 K with a cooling tower and 6–8 K with once-through water. A larger rise means less water but a higher condenser pressure.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.