Worked example
Example: 40 t/h at 0.1 bar(a), 90 % dry, CW 32 to 41 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Exhaust steam flow to the condenser | 40,000 kg/h |
| Exhaust steam dryness fraction | 90.000 % |
| Condenser pressure (absolute) | 10.000 kPa |
| Condensate subcooling below saturation | 0 K |
| Cooling water inlet temperature | 32.000 °C |
| Cooling water outlet temperature | 41.000 °C |
| Cooling water pressure (absolute) | 3.0000 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Condenser heat load | 23.921 MW |
| Cooling water flow | 2,289,974 kg/h |
| Cooling water volume flow | 2,301.2 m³/h |
| Saturation temperature in the condenser | 45.808 °C |
| Exhaust steam enthalpy | 2,344.7 kJ/kg |
| Condensate enthalpy | 191.81 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_s\,(h_{in} - h_c) \qquad h_{in} = h_f + x\,h_{fg} \ \text{at}\ p_c \qquad h_c = h(p_c,\ T_{sat} - \Delta T_{sub})\)
\(\dot m_{cw} = \frac{\dot Q}{h(T_{cw,2}) - h(T_{cw,1})} \qquad \dot V_{cw} = \frac{\dot m_{cw}}{\rho(T_{cw,1})} \quad \text{(water properties at } p_{cw}\text{)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | exhaust steam flow | kg/s |
| \(x\) | exhaust steam dryness | – |
| \(p_c\) | condenser pressure, absolute | Pa |
| \(\Delta T_{sub}\) | condensate subcooling | K |
| \(T_{cw,1}\) | cooling water inlet temperature | K |
| \(T_{cw,2}\) | cooling water outlet temperature | K |
| \(p_{cw}\) | cooling water pressure, absolute | Pa |
| \(\dot Q\) | condenser heat load | W |
| \(\dot m_{cw}\) | cooling water mass flow | kg/s |
| \(\dot V_{cw}\) | cooling water volume flow | m³/s |
| \(T_{sat}\) | saturation temperature | K |
| \(h_{in}\) | exhaust steam enthalpy | J/kg |
| \(h_c\) | condensate enthalpy | J/kg |
| \(h_f\), \(h_{fg}\) | saturated liquid enthalpy and latent heat at \(p_c\) | J/kg |
| \(\rho\) | water density | kg/m³ |
Method and standards
Energy balance of the condenser; steam, condensate and cooling water properties by FireCAD's IAPWS-IF97. Terms (TTD, ITD, heat load) as used in the HEI condenser standards.
Where it is used
- Sizing condensers and cooling water pumps for captive and utility turbines.
- Cooling tower sizing: the condenser load is most of the tower load.
- Checking condenser performance against design.
Common mistakes
- Assuming dry exhaust steam.
- Forgetting other loads on the condenser: drains, gland steam, turbine bypass.
- Using the cooling water outlet temperature from a probe close to the outlet water box, where it is not mixed.
Assumptions and limits
- Exhaust wet or saturated at condenser pressure; condensate at saturation unless subcooling is entered; no air in the steam.
- Only the turbine exhaust is counted. Heater drains, gland steam, turbine bypass and other flows dumped into the condenser add to the load; include them in the steam flow at their own enthalpy.
References
- IAPWS R7-97(2012) IF97
- HEI Standards for Steam Surface Condensers (terminology)
Questions and answers
How do I calculate condenser heat load?
Steam flow times the enthalpy it gives up. 40 t/h of 90 % dry exhaust at 0.1 bar(a) condensing to saturated water gives 23.9 MW; cooling water rising from 32 to 41 °C needs 636 kg/s, about 2300 m³/h.
Why does dryness matter?
Wet steam has already lost part of its latent heat. Assuming dry exhaust overstates the load by the moisture share, about 10 %.
What cooling water rise should I choose?
Usually 8–10 K with a cooling tower and 6–8 K with once-through water. A larger rise means less water but a higher condenser pressure.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.