Worked example
Example: 6 m duct at 400 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Duct width (across the tubes, along the shedding direction) | 6.0000 m |
| Gas temperature | 400.00 °C |
| Ratio of specific heats | 1.3500 - |
| Gas molar mass | 28.500 kg/kmol |
| Vortex-shedding frequency | 80.000 Hz |
Applying the formula below gives:
| Result | Value |
|---|---|
| Speed of sound | 514.89 m/s |
| First mode | 42.908 Hz |
| Second mode | 85.816 Hz |
| Third mode | 128.72 Hz |
| Shedding to first-mode ratio | 1.8645 |
Open this example in the calculator and change any input.
Formula
\(c = \sqrt{\frac{\gamma R T}{M}}, \quad f_n = \frac{n c}{2W}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Duct width (across the tubes, along the shedding direction) | m |
| \(T\) | Gas temperature | K |
| \(\gamma\) | Ratio of specific heats | - |
| \(M\) | Gas molar mass | kg/kmol |
| \(f_v\) | Vortex-shedding frequency | 1/s |
| \(c\) | Speed of sound | m/s |
| \(f_1\) | First mode | 1/s |
| \(f_2\) | Second mode | 1/s |
| \(f_3\) | Third mode | 1/s |
| \(f_v/f_1\) | Shedding to first-mode ratio | - |
Method and standards
Transverse standing waves across the duct width: the \(n\)-th mode has \(n\) half wavelengths across \(W\), at the ideal-gas speed of sound. The calculator warns when the shedding frequency is within 20 % of any of the first five modes, a common screening band; the first three modes are shown.
Where it is used
- Economiser, air heater and convection bank checks.
Common mistakes
- Width taken along the flow.
Assumptions and limits
- Rigid duct walls.
- Free-gas speed of sound: in a dense tube bank the effective speed of sound is lower (by about \(1/\sqrt{1 + \sigma}\) with \(\sigma\) the bank solidity), so the true mode frequencies are somewhat lower than shown.
References
- Transverse standing waves f_n = n c/(2W)
- c = √(γRT/M); Blevins
- Flow-Induced Vibration
- 2nd ed. (Van Nostrand Reinhold, 1990); Eisinger
- papers on tube-bank acoustic resonance
Questions and answers
Why do boiler banks 'sing'?
Vortex shedding locks onto a transverse acoustic mode of the duct and pumps sound energy.
Cure?
Anti-vibration baffles parallel to the flow split the duct width and raise the acoustic frequencies.
Which temperature?
The local gas temperature in the bank; modes shift as load changes.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.