Worked example
Example: 50 % moisture. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Moisture % bagasse | 50.000 % |
| Ash % bagasse | 2.5000 % |
| Brix % bagasse | 2.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gross calorific value, as fired | 9,250.1 kJ/kg |
| Net calorific value, as fired | 7,375.0 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(GCV = 19605 - 196.05\,W - 196.05\,A - 31.14\,B \;\; \mathrm{kJ/kg}\)
\(NCV = 18309 - 207.63\,W - 196.09\,A - 31.14\,B\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Moisture % bagasse | - |
| \(A\) | Ash % bagasse | - |
| \(B\) | Brix % bagasse | - |
| \(GCV\) | Gross calorific value, as fired | J/kg |
| \(NCV\) | Net calorific value, as fired | J/kg |
Method and standards
The net value is the South African formula printed in Hugot, Handbook of Cane Sugar Engineering, 3rd ed. (1986), p. 923 (B brix, W moisture, A ash, all % bagasse). The gross value takes the dry ash-free gross value of 19 605 kJ/kg in proportion to the combustible share, 19 605 (1 − W/100 − A/100), with the same brix term; Hugot gives other gross forms on pp. 922–923, for example 4600 − 12 s − 46 w kcal/kg (s sucrose, w moisture, % bagasse).
Where it is used
- Bagasse boiler efficiency and steam-to-fuel ratio.
- Bagasse surplus and cogeneration studies.
Common mistakes
- Moisture as a fraction in the % formula.
- Mixing GCV and NCV efficiencies.
Assumptions and limits
- Cane bagasse; W, A, B in % of bagasse.
- Very wet or ashy bagasse gives a zero or negative NCV, which is not shown; a non-positive GCV stops the page.
- The net formula is used as printed. The gross formula is the dry ash-free gross value scaled by the combustible share, not a printed equation.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (1986)
- p. 923: South African NCV = 18 309 − 31.14 B − 207.63 W − 196.09 A kJ/kg; GCV on the same basis from the dry ash-free gross value 19 605 kJ/kg
Questions and answers
Why does brix lower the value?
Sugar burns with less heat than fibre, so dissolved solids lower the value of the dry matter.
Which value for boiler efficiency?
Use the GCV for efficiency on the gross basis and the NCV for the net basis; state which.
Where do the constants come from?
Dry ash-free bagasse gives 19 605 kJ/kg gross and 18 309 kJ/kg net; moisture also takes latent heat in the net value.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.