FireCADCalc

Multiple-Effect Evaporator Design (Hugot)

Evaporation, brix, Dessin coefficient and heating surface of each effect of a 3- to 5-effect evaporator with vapour bleeding, by Hugot's method (pp. 588–591).

Sugar mill and cogeneration

Inputs

Examples: Hugot example: quadruple 120/111/100/85/55Quintuple with bleeding

Results

Hugot's example (100 t/h juice, 13 to 65 brix, quadruple 120/111/100/85/55 °C) gives 697, 482, 437 and 317 m², about 1 930 m² in all.

Total evaporation119,118kg/h
Vapour to the condenser12,424kg/h
Evaporation of effect 1 (= heating steam, Rillieux)43,424kg/h
Evaporation of effect 228,424kg/h
Evaporation of effect 320,424kg/h
Evaporation of effect 414,424kg/h
Evaporation of effect 512,424kg/h
Brix leaving effect 119.704%
Brix leaving effect 226.870%
Brix leaving effect 336.377%
Brix leaving effect 448.492%
Brix leaving effect 568.000%
Heating surface of effect 11,104.0m²
Heating surface of effect 2812.01m²
Heating surface of effect 3644.18m²
Heating surface of effect 4515.55m²
Heating surface of effect 5580.00m²
Total heating surface3,655.8m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: quadruple 120/111/100/85/55. The inputs, in the units selected above:

InputValue
Clear juice to the evaporator100.00 t/h
Clear juice brix13.000 %
Syrup brix65.000 %
Number of effects4.0000 -
Dessin factor0.001000 -
Heating steam temperature (effect 1)120.00 °C
Vapour temperature leaving effect 1111.00 °C
Vapour temperature leaving effect 2100.00 °C
Vapour temperature leaving effect 385.000 °C
Vapour temperature leaving effect 455.000 °C
Vapour temperature leaving effect 555.000 °C
Boiling-point rise in effect 1 (brix and head)0.80000 K
Boiling-point rise in effect 2 (brix and head)1.3000 K
Boiling-point rise in effect 3 (brix and head)2.1000 K
Boiling-point rise in effect 4 (brix and head)6.1000 K
Boiling-point rise in effect 5 (brix and head)6.1000 K
Vapour bled from effect 111,204 kg/h
Vapour bled from effect 23,515.0 kg/h
Vapour bled from effect 36,050.0 kg/h
Vapour bled from effect 40 kg/h

Applying the formula below gives:

ResultValue
Total evaporation80,000 kg/h
Vapour to the condenser10,904 kg/h
Evaporation of effect 1 (= heating steam, Rillieux)31,673 kg/h
Evaporation of effect 220,469 kg/h
Evaporation of effect 316,954 kg/h
Evaporation of effect 410,904 kg/h
Evaporation of effect 50 kg/h
Brix leaving effect 119.026 %
Brix leaving effect 227.164 %
Brix leaving effect 342.066 %
Brix leaving effect 465.000 %
Brix leaving effect 50 %
Heating surface of effect 1696.82 m²
Heating surface of effect 2481.39 m²
Heating surface of effect 3436.96 m²
Heating surface of effect 4316.72 m²
Heating surface of effect 50 m²
Total heating surface1,931.9 m²

Open this example in the calculator and change any input.

Formula

\(E = J\left(1 - \frac{B_0}{B_s}\right) = n x + \sum_{i<n} i P_i, \quad q_i = x + \sum_{k \ge i}P_k, \quad B_i = \frac{B_0 J}{J - \sum_{k \le i} q_k}\)

\(b_i = \frac{B_{i-1} + B_i}{2}, \quad c_i = f(100 - b_i)(T_{i-1} - 54), \quad \Delta_i = T_{i-1} - T_i - d_i, \quad S_i = \frac{q_i}{c_i\Delta_i}\)

Variables

Symbol Meaning SI unit
\(J\) Clear juice to the evaporator kg/s
\(B_0\) Clear juice brix -
\(B_s\) Syrup brix -
\(n\) Number of effects -
\(f\) Dessin factor -
\(T_0\) Heating steam temperature (effect 1) K
\(T_1\) Vapour temperature leaving effect 1 K
\(T_2\) Vapour temperature leaving effect 2 K
\(T_3\) Vapour temperature leaving effect 3 K
\(T_4\) Vapour temperature leaving effect 4 K
\(T_5\) Vapour temperature leaving effect 5 K
\(d_1\) Boiling-point rise in effect 1 (brix and head) K
\(d_2\) Boiling-point rise in effect 2 (brix and head) K
\(d_3\) Boiling-point rise in effect 3 (brix and head) K
\(d_4\) Boiling-point rise in effect 4 (brix and head) K
\(d_5\) Boiling-point rise in effect 5 (brix and head) K
\(P_1\) Vapour bled from effect 1 kg/s
\(P_2\) Vapour bled from effect 2 kg/s
\(P_3\) Vapour bled from effect 3 kg/s
\(P_4\) Vapour bled from effect 4 kg/s
\(E\) Total evaporation kg/s
\(x\) Vapour to the condenser kg/s
\(q_1\) Evaporation of effect 1 (= heating steam, Rillieux) kg/s
\(q_2\) Evaporation of effect 2 kg/s
\(q_3\) Evaporation of effect 3 kg/s
\(q_4\) Evaporation of effect 4 kg/s
\(q_5\) Evaporation of effect 5 kg/s
\(B_1\) Brix leaving effect 1 -
\(B_2\) Brix leaving effect 2 -
\(B_3\) Brix leaving effect 3 -
\(B_4\) Brix leaving effect 4 -
\(B_5\) Brix leaving effect 5 -
\(S_1\) Heating surface of effect 1 m²
\(S_2\) Heating surface of effect 2 m²
\(S_3\) Heating surface of effect 3 m²
\(S_4\) Heating surface of effect 4 m²
\(S_5\) Heating surface of effect 5 m²
\(S\) Total heating surface m²

Method and standards

Hugot's multiple-effect method with Dessin's coefficient.

Where it is used

  • Evaporator design and expansion.
  • Planning vapour bleeding.

Common mistakes

  • Bleeding more than the effects evaporate.
  • Leaving out the hydrostatic rise in d.

Assumptions and limits

  • Juice enters at its boiling point; add the first-vessel heating surface separately.
  • Rillieux idealisation: 1 kg of steam or vapour evaporates 1 kg, so the steam to effect 1 equals q₁; flash, heat losses and changing latent heat are ignored.
  • In the Dessin coefficient b_i is the mean of the brix entering and leaving the effect, in per cent.
  • The boiling-point rises d_i are entered, not computed from brix and liquid head.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • multiple-effect calculations
  • eqns 32.20 and 32.31 and the example of pp. 588–591

Questions and answers

How is each effect's evaporation found?

The last effect sends x to the condenser; every effect also supplies the vapour bled from it and from the effects after it, so E = n x + Σ i Pᵢ.

What mean brix does Hugot use?

The average of the brix entering and leaving each effect.

Are the surfaces final?

They are design values at the chosen temperatures; Hugot then checks the minimum-total-surface distribution.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.