Worked example
Example: Quadruple 54.7 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of effects | 4.0000 - |
| Total net temperature drop | 54.700 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Drop in effect 1 | 7.8143 K |
| Drop in effect 2 | 9.3771 K |
| Drop in effect 3 | 12.503 K |
| Drop in effect 4 | 25.006 K |
| Drop in effect 5 | 0 K |
Open this example in the calculator and change any input.
Formula
\(\Delta_n = 1, \quad \Delta_i = \frac{\sum_{j>i}\Delta_j}{2(n - i)}, \quad \text{scaled so that } \sum\Delta_i = \Delta\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(n\) | Number of effects | - |
| \(\Delta\) | Total net temperature drop | K |
| \(\Delta_1\) | Drop in effect 1 | K |
| \(\Delta_2\) | Drop in effect 2 | K |
| \(\Delta_3\) | Drop in effect 3 | K |
| \(\Delta_4\) | Drop in effect 4 | K |
| \(\Delta_5\) | Drop in effect 5 | K |
Method and standards
Hugot's minimum-surface condition for equal vessels.
Where it is used
- Checking an existing set of equal vessels.
- First estimate of temperatures.
Common mistakes
- Using the apparent instead of the net drop.
- Applying it with heavy bleeding.
Assumptions and limits
- No vapour bleeding; equal surfaces.
- Hugot's proportions start at the triple effect; for n = 2 the same rule is applied by extension and a note says so. Drops for effects beyond n are shown as zero.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- multiple effect with equal vessels
- p. 596 (from eqns 32.40–32.43)
Questions and answers
Why does the last vessel take the biggest drop?
Its thick syrup evaporates least per degree, so with equal surfaces it needs the largest drop.
Does this hold with bleeding?
No: it is Hugot's case without vapour bleeding; use the minimum-surface method with real evaporations.
Where does the rule come from?
The condition for minimum total surface with equal vessels: each drop is the sum of the later drops over 2(n − i).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.