FireCADCalc

Evaporator Calandria: Tubes, Pitch and Diameter

Number of tubes for a heating surface, tube pitch and calandria diameter of a short-tube (Robert) evaporator from Hugot's tube-plate ratios (eqns 32.10–32.15).

Sugar mill and cogeneration

Inputs

Examples: 1000 m2, 45 mm tubesFirst effect 4 m tubes

Hugot: 0.45–0.55.
Hugot: 0.33–0.38 overall, allowing for downtake and rim.
Hugot: 1/4 to 1/8.

Results

Ligament between tubes 15.6 mm; Hugot's practice is about one third of the tube diameter.

Hugot's tube lengths fall along the set (about 4 m in the first vessel to 2.25 m in the last); longer tubes need smaller diameters for the same circulation.

Number of tubes3,369.0
Tube pitch60.585mm
Calandria diameter4.0630m
Downtake diameter0.81260m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1000 m2, 45 mm tubes. The inputs, in the units selected above:

InputValue
Heating surface (inside of tubes)1,000.0 m²
Tube outside diameter45.000 mm
Tube wall1.5000 mm
Tube length2.2500 m
Tube-plate ratio, outside tube area / plate50.000 %
Inside tube section / calandria section36.000 %
Downtake / calandria diameter20.000 %

Applying the formula below gives:

ResultValue
Number of tubes3,369.0
Tube pitch60.585 mm
Calandria diameter4.0630 m
Downtake diameter0.81260 m

Open this example in the calculator and change any input.

Formula

\(N = \frac{S}{\pi d_i L}, \quad p = \frac{0.952\,d_e}{\sqrt{k_e}}, \quad D = \sqrt{\frac{4}{\pi}\frac{N\pi d_i^2/4}{k}}, \quad d_d = r_d D\)

Variables

Symbol Meaning SI unit
\(S\) Heating surface (inside of tubes) m²
\(d_e\) Tube outside diameter m
\(e\) Tube wall m
\(L\) Tube length m
\(k_e\) Tube-plate ratio, outside tube area / plate -
\(k\) Inside tube section / calandria section -
\(r_d\) Downtake / calandria diameter -
\(N\) Number of tubes -
\(p\) Tube pitch m
\(D\) Calandria diameter m
\(d_d\) Downtake diameter m

Method and standards

Hugot's tube-plate relations.

Where it is used

  • First layout of evaporator bodies.
  • Checking quotations.

Common mistakes

  • Using outside diameter with inside-surface figures.
  • Too close a pitch to expand tubes.

Assumptions and limits

  • Triangular pitch; uniform tube field.
  • The pitch (from k_e) and the diameter (from k) come from separate ratios. A note checks that the triangular tube field, N(√3/2)p², fits in the plate outside the downtake, and gives the ligament p − d_e for comparison with Hugot's one third of the diameter.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • construction
  • eqns 32.10–32.15
  • pp. 504–511

Questions and answers

Inside or outside surface?

Hugot (French practice) counts the inside of the tubes; American practice counts the outside, about 8 % more.

Why ligament about d/3?

Enough metal between holes for expanding the tubes; Hugot's pitch p = 1.35 d for k_e = 0.5.

Why a downtake?

Juice rises in the tubes and returns through the central well, giving circulation.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.