Worked example
Example: Hugot check: brix 15, 120 °C, 8.2 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean brix in the vessel | 15.000 % |
| Heating steam or vapour temperature | 120.00 °C |
| True temperature drop (steam to boiling juice) | 8.2000 K |
| Heating surface | 700.00 m² |
| Dessin factor | 0.001000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific evaporation coefficient, kg/(m²·h·°C) | 5.6100 |
| Evaporation per m² | 46.002 kg/(m²·h) |
| Evaporation | 32,201 kg/h |
Open this example in the calculator and change any input.
Formula
\(c = f(100 - b)(T - 54) \;[\mathrm{kg/(m^2\,h\,^\circ C)};\ b\ \%;\ T\ ^\circ C], \quad g = c\Delta, \quad E = g S\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(b\) | Mean brix in the vessel | - |
| \(T\) | Heating steam or vapour temperature | K |
| \(\Delta\) | True temperature drop (steam to boiling juice) | K |
| \(S\) | Heating surface | m² |
| \(f\) | Dessin factor | - |
| \(c\) | Specific evaporation coefficient, kg/(m²·h·°C) | - |
| \(g\) | Evaporation per m² | kg/(m²·s) |
| \(E\) | Evaporation | kg/s |
Method and standards
Dessin's formula as given by Hugot.
Where it is used
- Designing and checking multiple effects.
- Comparing vessels.
Common mistakes
- Using the apparent drop between vapour temperatures.
- Brix as a fraction.
Assumptions and limits
- Robert (short-tube) vessels.
- The true drop is entered by you and is not checked against the boiling-point elevation and hydrostatic head; the note gives Hugot's check case only.
- c is in kg/(m²·h·°C) in every unit system (there is no unit list for it).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 32
- eqn 32.31 (Dessin) and Table 32.18
- pp. 576–580
Questions and answers
Why does brix appear?
Thick syrup is viscous and boils sluggishly, so later effects evaporate less per degree.
Why T − 54?
Dessin's fit: the coefficient falls towards zero as the heating temperature approaches about 54 °C.
Which drop?
The true drop: heating steam temperature minus the boiling temperature of the juice, after boiling-point elevation and head.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.