FireCADCalc

Beer Preheating by Stillage: Heat Recovery

Heat recovered and the beer outlet temperature when beer is preheated by hot stillage in a counter-flow exchanger with a given approach at the cold end.

Distillery and ethanol

Inputs

Examples: 100 t/h beer at 32 °C, stillage 105 °CClose approach 6 K

Results

Stillage fouls quickly: use wide-gap plate or spiral exchangers and allow for cleaning.

Heat recovered5,568.8kW
Stillage out36.000°C
Beer out93.441°C
Log-mean temperature difference7.2037K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 t/h beer at 32 °C, stillage 105 °C. The inputs, in the units selected above:

InputValue
Beer flow100.00 t/h
Beer specific heat4.0000 kJ/(kg·K)
Beer in32.000 °C
Stillage flow90.000 t/h
Stillage specific heat4.0500 kJ/(kg·K)
Stillage in105.00 °C
Approach: stillage out minus beer in10.000 K

Applying the formula below gives:

ResultValue
Heat recovered6,378.8 kW
Stillage out42.000 °C
Beer out89.409 °C
Log-mean temperature difference12.589 K

Open this example in the calculator and change any input.

Formula

\(T_{s,out} = T_{b,in} + \Delta T_{ap}, \quad Q = \dot m_s c_s (T_{s,in} - T_{s,out}), \quad T_{b,out} = T_{b,in} + \frac{Q}{\dot m_b c_b}\)

Variables

Symbol Meaning SI unit
\(\dot m_b\) Beer flow kg/s
\(c_b\) Beer specific heat J/(kg·K)
\(T_{b,in}\) Beer in K
\(\dot m_s\) Stillage flow kg/s
\(c_s\) Stillage specific heat J/(kg·K)
\(T_{s,in}\) Stillage in K
\(\Delta T_{ap}\) Approach: stillage out minus beer in K
\(Q\) Heat recovered W
\(T_{s,out}\) Stillage out K
\(T_{b,out}\) Beer out K
\(\Delta T_{lm}\) Log-mean temperature difference K

Method and standards

Heat balance with a cold-end approach.

Where it is used

  • Distillery heat integration.
  • Steam saving studies.

Common mistakes

  • Ignoring fouling margin.
  • Using water specific heats for stillage.

Assumptions and limits

  • No phase change; no losses.
  • The cold-end approach is imposed. When the beer is the smaller capacity stream the hot end pinches first; a note appears when the hot-end difference falls below 5 K.

References

  • Counter-flow heat balance and log-mean temperature difference (definitions)

Questions and answers

Why preheat the beer?

Beer fed near its boiling point cuts the beer column steam by roughly a third.

Why fix the cold-end approach?

With stillage flow close to beer flow, the cold end usually pinches.

What fouls?

Stillage solids and proteins; spiral or wide-gap plates resist it.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.