Worked example
Example: Hugot example: 30 t/h, 1 %, 24 -> 40 °C, parallel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Sugar to dry | 30.000 t/h |
| Moisture of the wet sugar | 1.0000 % |
| Ambient air | 24.000 °C |
| Air leaving the dryer | 40.000 °C |
| Air leaving the heater | 90.000 °C |
| Air flow | Parallel or other (3000) |
| Heating steam pressure (absolute) | 5.0000 bar |
| Air heater coefficient | 11.630 W/(m²·K) |
| Barometric pressure | 101.33 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturated humidity at ambient, kg/1000 kg | 18.882 |
| Saturated humidity at dryer exit, kg/1000 kg | 48.889 |
| Air | 29,994 kg/h |
| Air volume at ambient | 25,533 m³/h |
| Heat to the air heater | 982.52 kW |
| Steam | 1,678.0 kg/h |
| Air heater surface | 890.82 m² |
| Dryer volume (t/(dr) = 1.35 per % moisture) | 40.500 m³ |
Open this example in the calculator and change any input.
Formula
\(A = \frac{1500\,P h}{H_1 - H_0}\ (\text{counter-current}), \quad M = 1.25(q_1 + q_2 + q_3)\)
\(q_1 = A c (t_1 - t_0), \quad q_2 = P h(607 + 0.3t_1 - t_0), \quad q_3 = A\frac{H_0}{1000}c'(t_1 - t_0), \quad Q = \frac{M}{h_g - h_f}\)
\(S = \frac{M}{k\left(T - \frac{t_1 + t_0}{2}\right)}, \quad V_d = 1.35\,P\,h_{\%}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Sugar to dry | kg/s |
| \(h\) | Moisture of the wet sugar | - |
| \(t_0\) | Ambient air | K |
| \(t_e\) | Air leaving the dryer | K |
| \(t_1\) | Air leaving the heater | K |
| \(\text{flow}\) | Air flow | - |
| \(p_s\) | Heating steam pressure (absolute) | Pa |
| \(k\) | Air heater coefficient | W/(m²·K) |
| \(p_a\) | Barometric pressure | Pa |
| \(H_0\) | Saturated humidity at ambient, kg/1000 kg | - |
| \(H_1\) | Saturated humidity at dryer exit, kg/1000 kg | - |
| \(A\) | Air | kg/s |
| \(V\) | Air volume at ambient | m³/s |
| \(M\) | Heat to the air heater | W |
| \(Q\) | Steam | kg/s |
| \(S\) | Air heater surface | m² |
| \(V_d\) | Dryer volume (t/(dr) = 1.35 per % moisture) | m³ |
| \(c\) | Specific heat of air, 0.24 | kcal/(kg·°C) |
| \(c'\) | Specific heat of water vapour, 0.475 | kcal/(kg·°C) |
| \(q_1, q_2, q_3\) | Heat to the air, to evaporate the water, and to the vapour in the air | kcal/h |
| \(h_g - h_f\) | Latent heat of the heating steam (IF97) | J/kg |
Method and standards
Hugot's dryer method with IF97 saturation.
Where it is used
- Dryer and air heater sizing.
- Checking dryer steam use.
Common mistakes
- Using relative humidity of the air instead of saturation.
- Air too hot: it damages sugar.
Assumptions and limits
- Hugot's assumptions on exit saturation; kcal forms converted to SI. In q₂, 607 and 0.3 are Hugot's kcal/kg latent-heat constants (water vapour from water at t₀).
- Conservative: ambient air taken as saturated, and all the moisture h is removed (no final moisture).
- The air must leave the heater hotter than it leaves the dryer; ambient air from 0 °C upwards (IF97 saturation over water).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 36
- sugar dryers
- eqns 36.4–36.12 and example
- pp. 821–830
- Saturation pressure from IAPWS-IF97; humidity ratio from molar masses
Questions and answers
Why assume the ambient air saturated?
Hugot designs for the worst case; the air then has the least drying capacity.
Why 1500 or 3000?
Counter-current air leaves about two-thirds saturated, parallel flow about one-third; the constant folds that in.
How much steam?
Hugot quotes 2–3 kg per 100 kg of sugar for usual dryers; his air-quantity rule with hot parallel-flow air gives more, so check the air temperature and flow.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.