Sugar Dryer by Hugot: Air, Heat, Heater and Volume

Air, heat, steam and heater surface for a sugar dryer by Hugot's method (eqns 36.4–36.12) with saturated-air humidity from IF97, and the dryer volume for a moisture.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)Fan and blower

Inputs

Examples: Hugot example: 30 t/h, 1 %, 24 -> 40 °C, parallelCounter-current dryer

Hugot: 70–95 °C; not above 95–100 °C.

Results

Hugot's example: 30 t/h sugar at 1 % moisture, air 24 → 40 °C, parallel flow: about 30 000 kg/h of air. Keep air velocity below 2 m/s at the exit.

Conservative assumptions, as Hugot: ambient air taken as saturated (H₀ at saturation) and all the moisture h removed (no final moisture).

Saturated humidity at ambient, kg/1000 kg24.119
Saturated humidity at dryer exit, kg/1000 kg54.829
Air14,653kg/h
Air volume at ambient12,680m³/h
Heat to the air heater568.96kW
Steam960.13kg/h
Air heater surface561.60m²
Dryer volume (t/(dr) = 1.35 per % moisture)40.500m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: 30 t/h, 1 %, 24 -> 40 °C, parallel. The inputs, in the units selected above:

InputValue
Sugar to dry30.000 t/h
Moisture of the wet sugar1.0000 %
Ambient air24.000 °C
Air leaving the dryer40.000 °C
Air leaving the heater90.000 °C
Air flowParallel or other (3000)
Heating steam pressure (absolute)5.0000 bar
Air heater coefficient11.630 W/(m²·K)
Barometric pressure101.33 kPa

Applying the formula below gives:

ResultValue
Saturated humidity at ambient, kg/1000 kg18.882
Saturated humidity at dryer exit, kg/1000 kg48.889
Air29,994 kg/h
Air volume at ambient25,533 m³/h
Heat to the air heater982.52 kW
Steam1,678.0 kg/h
Air heater surface890.82 m²
Dryer volume (t/(dr) = 1.35 per % moisture)40.500 m³

Open this example in the calculator and change any input.

Formula

\(A = \frac{1500\,P h}{H_1 - H_0}\ (\text{counter-current}), \quad M = 1.25(q_1 + q_2 + q_3)\)

\(q_1 = A c (t_1 - t_0), \quad q_2 = P h(607 + 0.3t_1 - t_0), \quad q_3 = A\frac{H_0}{1000}c'(t_1 - t_0), \quad Q = \frac{M}{h_g - h_f}\)

\(S = \frac{M}{k\left(T - \frac{t_1 + t_0}{2}\right)}, \quad V_d = 1.35\,P\,h_{\%}\)

Variables

Symbol Meaning SI unit
\(P\) Sugar to dry kg/s
\(h\) Moisture of the wet sugar -
\(t_0\) Ambient air K
\(t_e\) Air leaving the dryer K
\(t_1\) Air leaving the heater K
\(\text{flow}\) Air flow -
\(p_s\) Heating steam pressure (absolute) Pa
\(k\) Air heater coefficient W/(m²·K)
\(p_a\) Barometric pressure Pa
\(H_0\) Saturated humidity at ambient, kg/1000 kg -
\(H_1\) Saturated humidity at dryer exit, kg/1000 kg -
\(A\) Air kg/s
\(V\) Air volume at ambient m³/s
\(M\) Heat to the air heater W
\(Q\) Steam kg/s
\(S\) Air heater surface m²
\(V_d\) Dryer volume (t/(dr) = 1.35 per % moisture) m³
\(c\) Specific heat of air, 0.24 kcal/(kg·°C)
\(c'\) Specific heat of water vapour, 0.475 kcal/(kg·°C)
\(q_1, q_2, q_3\) Heat to the air, to evaporate the water, and to the vapour in the air kcal/h
\(h_g - h_f\) Latent heat of the heating steam (IF97) J/kg

Method and standards

Hugot's dryer method with IF97 saturation.

Where it is used

  • Dryer and air heater sizing.
  • Checking dryer steam use.

Common mistakes

  • Using relative humidity of the air instead of saturation.
  • Air too hot: it damages sugar.

Assumptions and limits

  • Hugot's assumptions on exit saturation; kcal forms converted to SI. In q₂, 607 and 0.3 are Hugot's kcal/kg latent-heat constants (water vapour from water at t₀).
  • Conservative: ambient air taken as saturated, and all the moisture h is removed (no final moisture).
  • The air must leave the heater hotter than it leaves the dryer; ambient air from 0 °C upwards (IF97 saturation over water).

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 36
  • sugar dryers
  • eqns 36.4–36.12 and example
  • pp. 821–830
  • Saturation pressure from IAPWS-IF97; humidity ratio from molar masses

Questions and answers

Why assume the ambient air saturated?

Hugot designs for the worst case; the air then has the least drying capacity.

Why 1500 or 3000?

Counter-current air leaves about two-thirds saturated, parallel flow about one-third; the constant folds that in.

How much steam?

Hugot quotes 2–3 kg per 100 kg of sugar for usual dryers; his air-quantity rule with hot parallel-flow air gives more, so check the air temperature and flow.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.