Worked example
Example: 40 x 100 m, 3 m walls, 34°. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Store width | 40.000 m |
| Store length | 100.00 m |
| Side-wall height | 3.0000 m |
| Angle of repose of the sugar | 34.000 ° |
| Bulk density in the pile | 880.00 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Height of the pile at the ridge | 16.490 m |
| Cross-section of sugar | 389.80 m² |
| Volume | 38,980 m³ |
| Sugar held | 34,303 t |
Open this example in the calculator and change any input.
Formula
\(h_r = h_w + \frac{W}{2}\tan\alpha, \quad A = W h_w + \frac{W^2}{4}\tan\alpha, \quad V = A\ell, \quad M = \rho V\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Store width | m |
| \(\ell\) | Store length | m |
| \(h_w\) | Side-wall height | m |
| \(\alpha\) | Angle of repose of the sugar | rad |
| \(\rho\) | Bulk density in the pile | kg/m³ |
| \(h_r\) | Height of the pile at the ridge | m |
| \(A\) | Cross-section of sugar | m² |
| \(V\) | Volume | m³ |
| \(M\) | Sugar held | kg |
Method and standards
Geometry of a prismatic pile.
Where it is used
- Sizing bulk stores.
- Season storage planning.
Common mistakes
- Using bag-store density for bulk.
- Ignoring the end slopes on short stores.
Assumptions and limits
- Prismatic pile filled to the angle of repose; the ridge height is not checked against the roof (a note gives it).
- The sloping ends are ignored. With the pile sloping at the angle of repose at both ends too, the ends hold about W³ tan α/12 less than the prism; a note gives the share when it exceeds 5 % (short stores).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 36
- bulk storage (Fig. 36.1)
- pp. 819–820; ch. 37
- densities
- p. 832
Questions and answers
Why does bulk sugar keep better than bagged?
The pile's surface forms a crust that keeps moisture out; dry sugar keeps for years.
Which density?
Hugot: 800–900 kg/m³, rising with depth as the pile compacts.
Why low side walls?
Sugar presses hard on walls; economic stores keep them near 3 m and let the pile rise to the roof.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.