Worked example
Example: 25 t/h, 1 % to 0.05 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Wet sugar to dryer | 25.000 t/h |
| Moisture in (wet basis) | 1.0000 % |
| Moisture out (wet basis) | 0.050000 % |
| Air humidity in | 8.0000 g/kg |
| Air humidity out | 12.000 g/kg |
| Air temperature out (to check saturation) | 40.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water removed | 237.62 kg/h |
| Dry air needed | 59,405 kg/h |
Open this example in the calculator and change any input.
Formula
\(\dot m_w = \dot m (1 - w_1)\left(\frac{w_1}{1-w_1} - \frac{w_2}{1-w_2}\right), \quad \dot m_a = \frac{\dot m_w}{Y_2 - Y_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Wet sugar to dryer | kg/s |
| \(w_1\) | Moisture in (wet basis) | - |
| \(w_2\) | Moisture out (wet basis) | - |
| \(Y_1\) | Air humidity in | kg/kg |
| \(Y_2\) | Air humidity out | kg/kg |
| \(T_e\) | Air temperature out (to check saturation) | K |
| \(\dot m_w\) | Water removed | kg/s |
| \(\dot m_a\) | Dry air needed | kg/s |
Method and standards
Mass balance.
Where it is used
- Dryer and cooler sizing.
Common mistakes
- Wet and dry basis mixed.
Assumptions and limits
- Steady state.
- The exit humidity must be below saturation at the exit air temperature (checked at 1 atm).
References
- Solids and moisture balance; air humidity balance (psychrometrics)
Questions and answers
Why so little water?
Sugar leaves the centrifugals with about 0.5–1.5 % moisture.
Why does it matter?
Moist sugar cakes and grows microbes in storage.
Air heated?
Heating raises the humidity it can take; then it needs a cooler stage.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.