Worked example
Example: Illustrative: 300 kN on a 600 x 500 mm concrete strip, k_s 20 MN/m3, 12 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Concentrated load | 300.00 kN |
| Modulus of subgrade reaction | 20.000 MN/m³ |
| Beam width in contact with the foundation | 0.60000 m |
| Elastic modulus of the beam | 30.000 GPa |
| Second moment of area of the beam | 625,000 cm⁴ |
| Distance from the load for the local values | 1.0000 m |
| Beam length (load near mid-length) | 12.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Characteristic length | 2.8117 m |
| Deflection under the load | 4.4457 mm |
| Bending moment under the load | 210.88 kN·m |
| Foundation pressure under the load | 88.914 kPa |
| Deflection at x | 4.0049 mm |
| Bending moment at x | 87.065 kN·m |
| Distance to the first zero of moment (π/4β) | 2.2083 m |
| βL (long beam above π) | 4.2679 |
Open this example in the calculator and change any input.
Formula
\(\beta = \sqrt[4]{\frac{k_s b}{4EI}}, \quad y_0 = \frac{P\beta}{2k_s b}, \quad M_0 = \frac{P}{4\beta}, \quad p_0 = k_s y_0\)
\(y(x) = y_0 e^{-\beta x}(\cos\beta x + \sin\beta x), \quad M(x) = M_0 e^{-\beta x}(\cos\beta x - \sin\beta x)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Concentrated load | N |
| \(k_s\) | Modulus of subgrade reaction | N/m³ |
| \(b\) | Beam width in contact with the foundation | m |
| \(E\) | Elastic modulus of the beam | Pa |
| \(I\) | Second moment of area of the beam | m⁴ |
| \(x\) | Distance from the load for the local values | m |
| \(L\) | Beam length (load near mid-length) | m |
| \(1/\beta\) | Characteristic length | m |
| \(y_0\) | Deflection under the load | m |
| \(M_0\) | Bending moment under the load | N·m |
| \(p_0\) | Foundation pressure under the load | Pa |
| \(y(x)\) | Deflection at x | m |
| \(M(x)\) | Bending moment at x | N·m |
| \(x_{M=0}\) | Distance to the first zero of moment (π/4β) | m |
| \(\beta L\) | βL (long beam above π) | - |
Method and standards
Hetényi's solution of EI y'''' + k_s b y = 0 for an infinite beam.
Where it is used
- Combined and strip footings, grade beams.
- Rails on ballast and crane rails on concrete.
Common mistakes
- Using the plate-test k_s for a much wider footing without scaling.
- Applying the infinite-beam result to a short stiff beam.
Assumptions and limits
- Linear elastic Winkler foundation that also acts in tension; infinite beam.
References
- Winkler elastic foundation
- infinite-beam solution for a concentrated load
Questions and answers
What is the modulus of subgrade reaction?
The pressure per unit settlement of the soil, k_s in MN/m³; it depends on the loaded width and is usually taken from a plate load test scaled to the footing size.
Why does the moment change sign?
The beam lifts slightly away from the load (the deflection becomes negative beyond 3π/4β), so the moment reverses at π/4β.
What do the defaults represent?
An illustrative 600 × 500 mm concrete strip beam, 12 m long, on soil with k_s = 20 MN/m³, carrying a 300 kN column load.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Hetényi, Beams on Elastic Foundation (University of Michigan Press, 1946), ch. II, Young and Budynas, Roark's Formulas for Stress and Strain, 7th ed. (McGraw-Hill, 2002), Table 8.5 case 8