FireCADCalc

Specific Fuel Consumption Converter (g/kWh, lb/hp·h, L/kWh)

Convert engine or generator specific fuel consumption between g/kWh, lb/(hp·h), kg/kWh and L/kWh, with the efficiency and heat rate it implies.

Inputs

Examples: Diesel engine 210 g/kWh0.36 lb/(hp h) on natural gas basis

Accepted: 3.6 to 3,600 g/kWh
Accepted: 1,000 to 150,000 kJ/kg
Accepted: 100 to 2,000 kg/m³

Results

Specific fuel consumption times the net calorific value is the heat rate; its reciprocal is the efficiency. 210 g/kWh of diesel at 42.7 MJ/kg is 8,967 kJ/kWh, 40.1 %. Engine data sheets quote SFC at the crankshaft (per kW mechanical); generator sets per kWe, which includes the alternator loss.

SFC in g/kWh218.98g/kWh
SFC in lb/(hp·h)0.36000lb/(hp·h)
Volume consumption0.29197L/kWh
Fuel-to-power efficiency on NCV34.250%
Heat rate on NCV10,511kJ/kWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Diesel engine 210 g/kWh. The inputs, in the units selected above:

InputValue
Specific fuel consumption (choose its unit)210.00 g/kWh
Net calorific value of the fuel42,700 kJ/kg
Fuel density (for the volume figure)840.00 kg/m³

Applying the formula below gives:

ResultValue
SFC in g/kWh210.00 g/kWh
SFC in lb/(hp·h)0.34524 lb/(hp·h)
Volume consumption0.25000 L/kWh
Fuel-to-power efficiency on NCV40.147 %
Heat rate on NCV8,967.0 kJ/kWh

Open this example in the calculator and change any input.

Formula

\(HR = SFC \cdot NCV, \quad \eta = \frac{1}{SFC \cdot NCV}, \quad SFC_v = \frac{SFC}{\rho}\)

Variables

Symbol Meaning SI unit
\(SFC\) Specific fuel consumption (choose its unit) kg/J
\(NCV\) Net calorific value of the fuel J/kg
\(\rho\) Fuel density (for the volume figure) kg/m³
\(SFC_v\) Volume consumption m³/J
\(\eta\) Fuel-to-power efficiency on NCV -
\(HR\) Heat rate on NCV J/J

Method and standards

Specific fuel consumption.

Where it is used

  • Comparing engine data sheets in g/kWh and lb/(hp·h).
  • Checking a generator set's fuel bills.

Common mistakes

  • Comparing crankshaft SFC with generator-terminal SFC.
  • Using the gross calorific value with a net-basis figure.

Assumptions and limits

  • Mass-based SFC; NCV basis.

References

  • Unit definitions per NIST SP 811 and the SI Brochure (exact where defined)
  • Heat rate = SFC × NCV

Questions and answers

What efficiency is 200 g/kWh?

With diesel at 42.7 MJ/kg, 3600 / (0.200 × 42,700) = 42.2 %.

How many litres per kWh does a diesel generator use?

About 0.25 to 0.30 L/kWh at good load: 210 to 250 g/kWh divided by about 840 g/L.

What do the defaults represent?

210 g/kWh with diesel (42.7 MJ/kg NCV, 840 kg/m³), typical of a medium-speed engine.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators