Worked example
Example: Copper and drinking water. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Resistivity (choose its unit) | 0.017200 Ω·mm²/m |
| Conductivity (choose its unit) | 100.00 µS/cm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ω·m | 1.7200e-08 Ω·m |
| Ω·mm²/m | 0.017200 Ω·mm²/m |
| µΩ·cm | 1.7200 µΩ·cm |
| Conductivity from the resistivity | 5.8140e+07 S/m |
| S/m | 0.010000 S/m |
| mS/cm | 0.10000 mS/cm |
| µS/cm | 100.00 µS/cm |
| Resistivity from the conductivity | 100.00 Ω·m |
Open this example in the calculator and change any input.
Formula
\(\kappa = \frac1\rho, \quad 1\ \mu\text{S/cm} = 10^{-4}\ \text{S/m}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Resistivity (choose its unit) | Ω·m |
| \(\kappa\) | Conductivity (choose its unit) | S/m |
| \(1/\rho\) | Conductivity from the resistivity | S/m |
| \(1/\kappa\) | Resistivity from the conductivity | Ω·m |
Method and standards
Resistivity units.
Where it is used
- Conductor and cable calculations.
- Water purity and boiler water monitoring.
Common mistakes
- Forgetting the reciprocal relation.
- Mixing µS/cm with µS/m.
Assumptions and limits
- Exact factors.
References
- Unit definitions per NIST SP 811 and the SI Brochure (exact where defined)
Questions and answers
What resistivity does 0.055 µS/cm correspond to?
18.2 MΩ·cm (1.82 × 10⁵ Ω·m), ultrapure water.
What is copper's resistivity in Ω·m?
1.72 × 10⁻⁸ Ω·m, or 0.0172 Ω·mm²/m.
What do the defaults represent?
Copper at 0.0172 Ω·mm²/m and water at 100 µS/cm (0.01 S/m).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.