FireCADCalc

Outdoor Swimming Pool Heat Loss, Solar Gain and Heating Load

Monthly radiation, evaporation and convection losses, solar gain and heating load of an outdoor pool, with the effect of a film or bubble cover at night.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Same pool with a bubble cover 12 hHotel pool 200 m2 at 28 C, winter month 18 C, 55 % RH, 15 MJ/m2, no cover

Accepted: 1 to 10,000 m²
Accepted: 11.85 to 41.85 °C
Accepted: -13.15 to 46.85 °C
Accepted: 5 to 100 %
Accepted: 60 to 110 kPa
Accepted: 0 to 10 m/s
Accepted: 0 to 40 MJ/m²
Accepted: 0 to 100 %
Accepted: 50 to 100 %
Accepted: 30 to 100 %
Accepted: 28 to 31
Accepted: 0 to 100 %

Results

Wei et al. (1979) evaporation and convection equations in W/m² with the pressure in kPa; the pool radiates as a black body to a sky temperature weighted by K̄_T between clear sky (Berdahl and Martin) and air. A negative load means the pool would warm above the set point.

Dew point8.8352°C
Mean sky temperature9.5602°C
Solar energy absorbed68.448GJ
Radiation loss55.796GJ
Evaporation loss (uncovered)134.49GJ
Convection loss (uncovered)47.267GJ
Heating load, never covered169.11GJ
Heating load with the cover169.11GJ

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same pool with a bubble cover 12 h. The inputs, in the units selected above:

InputValue
Pool surface area72.000 m²
Pool temperature25.000 °C
Monthly mean air temperature16.000 °C
Monthly mean relative humidity70.000 %
Air pressure101.33 kPa
Wind speed at the pool (1/5–1/10 of the weather-station value)3.0000 m/s
Monthly average daily radiation on a horizontal surface19.100 MJ/m²
Monthly clearness index (weighting of sky temperature)53.000 %
Surface transmittance92.000 %
Pool absorptance (0.6 to 0.9)60.000 %
Days in the month30.000 -
Share of the time covered50.000 %
Cover typeBubble cover (stops evaporation, cuts convection)

Applying the formula below gives:

ResultValue
Dew point10.538 °C
Mean sky temperature7.7381 °C
Solar energy absorbed22.773 GJ
Radiation loss17.748 GJ
Evaporation loss (uncovered)44.753 GJ
Convection loss (uncovered)19.855 GJ
Heating load, never covered59.583 GJ
Heating load with the cover27.279 GJ

Open this example in the calculator and change any input.

Formula

\(q_e = P_a[35V + 43(T_p - T_a)^{1/3}](\omega_p - \omega_a), \quad q_c = q_e\,0.0006\frac{T_p - T_a}{\omega_p - \omega_a}\)

\(Q_r = A\sigma(T_p^4 - \bar T_{sky}^4)\Delta t, \quad Q_s = A\bar H\tau\alpha N\)

Variables

Symbol Meaning SI unit
\(A\) Pool surface area m²
\(T_p\) Pool temperature K
\(\bar T_a\) Monthly mean air temperature K
\(\phi\) Monthly mean relative humidity -
\(P_a\) Air pressure Pa
\(V\) Wind speed at the pool (1/5–1/10 of the weather-station value) m/s
\(\bar H\) Monthly average daily radiation on a horizontal surface J/m²
\(\bar K_T\) Monthly clearness index (weighting of sky temperature) -
\(\tau\) Surface transmittance -
\(\alpha\) Pool absorptance (0.6 to 0.9) -
\(N\) Days in the month -
\(f_c\) Share of the time covered -
\(\text{cover}\) Cover type -
\(T_{dp}\) Dew point K
\(\bar T_{sky}\) Mean sky temperature K
\(Q_s\) Solar energy absorbed J
\(Q_r\) Radiation loss J
\(Q_e\) Evaporation loss (uncovered) J
\(Q_c\) Convection loss (uncovered) J
\(L_0\) Heating load, never covered J
\(L\) Heating load with the cover J

Method and standards

Monthly energy balance of an outdoor pool.

Where it is used

  • Sizing solar pool heaters and heat pumps.
  • Estimating cover savings.

Common mistakes

  • Using weather-station wind speed directly.
  • Forgetting evaporation, the largest loss.

Assumptions and limits

  • Monthly averages; empirical evaporation equation.

Questions and answers

Which loss is largest?

Evaporation, typically half or more of the total; that is why a cover saves so much.

Why use a reduced wind speed?

Pools are sheltered by fences and buildings; Wei et al. suggest one-fifth to one-tenth of the weather-station wind.

What do the defaults represent?

An illustrative case: Same pool with a bubble cover 12 h. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 9.7, eqs. 9.7.1 and 9.7.2 (Wei, Sigworth, Lederer and Bloom, 1979) and Example 9.7.1

Related calculators