FireCADCalc

Solar Collector Stagnation (No-Flow) Temperature

Plate temperature a flat-plate collector reaches with no flow, from absorbed radiation and Klein's top loss coefficient solved together with the plate temperature.

Inputs

Examples: Illustrative: 1050 W/m2, selective single-glazed collector, 35 C ambient, fluid boils at 140 CBlack-painted collector, 1150 W/m2, 38 C (pressurised glycol, 145 C)Double-glazed selective collector, 1000 W/m2, 30 C

Accepted: 100 to 1,400 W/m²
Accepted: 30 to 100 %
Accepted: 1 to 3
Accepted: 2 to 100 %
Accepted: 50 to 100 %
Accepted: 0 to 90 °
Accepted: -43.15 to 56.85 °C
Accepted: 1 to 100 W/(m²·K)
Accepted: 0.01 to 1 W/(m·K)
Accepted: 1 to 500 mm
Accepted: 0 to 10 W/(m²·K)
Accepted: 26.85 to 226.85 °C

Results

No-flow balance S = U_L(T_p − T_a) with U_L from Klein's top-loss equation, which rises with plate temperature, plus back and edge losses.

The fluid would boil in the collector at stagnation: provide pressure relief, a drain-back or overheat protection.

Stagnation plate temperature189.28°C
Loss coefficient at that temperature5.4446W/(m²·K)
Top loss coefficient4.3446W/(m²·K)
Absorbed radiation840.00W/m²
Margin to boiling (negative = boils)-49.282K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 1050 W/m2, selective single-glazed collector, 35 C ambient, fluid boils at 140 C. The inputs, in the units selected above:

InputValue
Radiation on the collector1,050.0 W/m²
Transmittance–absorptance product80.000 %
Number of glass covers1.0000 -
Plate emittance (selective 0.1, black paint 0.95)12.000 %
Glass emittance88.000 %
Collector slope40.000 °
Ambient temperature35.000 °C
Wind heat transfer coefficient8.0000 W/(m²·K)
Back insulation conductivity0.040000 W/(m·K)
Back insulation thickness50.000 mm
Edge loss coefficient0.30000 W/(m²·K)
Boiling point of the collector fluid at system pressure140.00 °C

Applying the formula below gives:

ResultValue
Stagnation plate temperature189.28 °C
Loss coefficient at that temperature5.4446 W/(m²·K)
Top loss coefficient4.3446 W/(m²·K)
Absorbed radiation840.00 W/m²
Margin to boiling (negative = boils)-49.282 K

Open this example in the calculator and change any input.

Formula

\(G_T(\tau\alpha) = U_L(T_{p}) \,(T_{p} - T_a), \quad U_L = U_t(T_p) + \frac{k_b}{L_b} + U_e\)

Variables

Symbol Meaning SI unit
\(G_T\) Radiation on the collector W/m²
\((\tau\alpha)\) Transmittance–absorptance product -
\(N\) Number of glass covers -
\(\varepsilon_p\) Plate emittance (selective 0.1, black paint 0.95) -
\(\varepsilon_g\) Glass emittance -
\(\beta\) Collector slope rad
\(T_a\) Ambient temperature K
\(h_w\) Wind heat transfer coefficient W/(m²·K)
\(k_b\) Back insulation conductivity W/(m·K)
\(L_b\) Back insulation thickness m
\(U_e\) Edge loss coefficient W/(m²·K)
\(T_{boil}\) Boiling point of the collector fluid at system pressure K
\(T_{p,stag}\) Stagnation plate temperature K
\(U_L\) Loss coefficient at that temperature W/(m²·K)
\(U_t\) Top loss coefficient W/(m²·K)
\(S\) Absorbed radiation W/m²
\(T_{boil} - T_{p,stag}\) Margin to boiling (negative = boils) K

Method and standards

No-flow energy balance with a temperature-dependent loss coefficient.

Where it is used

  • Overheat protection design.
  • Choosing heat transfer fluids and system pressure.

Common mistakes

  • Using a constant loss coefficient measured at normal temperatures.
  • Forgetting the summer worst case.

Assumptions and limits

  • Steady state, clear sky, Klein's correlation range.

References

  • Stagnation energy balance with Klein's top-loss equation

Questions and answers

Why does a selective absorber stagnate so hot?

Its low emittance cuts radiation loss, so the plate must get much hotter before losses balance the absorbed sunlight; 150–200 °C is common.

What happens to glycol at stagnation?

Above about 140 °C propylene glycol degrades and the fluid may boil; systems need relief valves, expansion volume or drain-back.

What do the defaults represent?

An illustrative summer case: 1,050 W/m² on a single-glazed selective collector (τα 0.80) at 35 °C ambient with a fluid boiling at 140 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 12.2 (Example 12.2.1) and eq. 6.4.9 (Klein's top loss)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.