Worked example
Example: Crop dryer collector: 2 m x 6 m, 50 mm channel, 0.15 kg/s, ambient inlet. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Collector width | 2.0000 m |
| Collector length (flow direction) | 6.0000 m |
| Air channel depth | 50.000 mm |
| Radiation on the collector | 800.00 W/m² |
| Effective transmittance–absorptance product | 80.000 % |
| Top loss coefficient | 5.5000 W/(m²·K) |
| Back and edge loss coefficient | 0.80000 W/(m²·K) |
| Emittance of the absorber underside | 90.000 % |
| Emittance of the duct back plate | 90.000 % |
| Inlet air temperature | 30.000 °C |
| Ambient temperature | 30.000 °C |
| Air mass flow | 540.00 kg/h |
| Air specific heat | 1.0070 kJ/(kg·K) |
| Air thermal conductivity | 0.026500 W/(m·K) |
| Air viscosity | 0.018600 mPa·s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Overall loss coefficient U_t + U_b | 6.3000 W/(m²·K) |
| Duct Reynolds number | 8,064.5 |
| Air-side coefficient (each duct wall) | 5.5868 W/(m²·K) |
| Radiation coefficient across the duct | 5.8790 W/(m²·K) |
| Collector efficiency factor | 57.292 % |
| Collector flow factor | 86.940 % |
| Heat removal factor | 49.810 % |
| Useful gain | 3,825.4 W |
| Outlet air temperature | 55.325 °C |
| Collector efficiency | 39.848 % |
| Mean air temperature | 43.267 °C |
| Mean absorber temperature | 80.987 °C |
Open this example in the calculator and change any input.
Formula
\(F' = \left[1 + \frac{U_L}{h + \left(1/h + 1/h_r\right)^{-1}}\right]^{-1}, \quad h_r = \frac{4\sigma\bar T^3}{1/\varepsilon_1 + 1/\varepsilon_2 - 1}\)
\(F_R = F'F'', \quad F'' = \frac{\dot mc_p}{A_cU_LF'}\left[1 - e^{-A_cU_LF'/(\dot mc_p)}\right], \quad Q_u = A_cF_R\left[G_T(\tau\alpha) - U_L(T_i - T_a)\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Collector width | m |
| \(L\) | Collector length (flow direction) | m |
| \(d\) | Air channel depth | m |
| \(G_T\) | Radiation on the collector | W/m² |
| \((\tau\alpha)\) | Effective transmittance–absorptance product | - |
| \(U_t\) | Top loss coefficient | W/(m²·K) |
| \(U_b\) | Back and edge loss coefficient | W/(m²·K) |
| \(\varepsilon_1\) | Emittance of the absorber underside | - |
| \(\varepsilon_2\) | Emittance of the duct back plate | - |
| \(T_i\) | Inlet air temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(\dot m\) | Air mass flow | kg/s |
| \(c_p\) | Air specific heat | J/(kg·K) |
| \(k\) | Air thermal conductivity | W/(m·K) |
| \(\mu\) | Air viscosity | Pa·s |
| \(U_L\) | Overall loss coefficient U_t + U_b | W/(m²·K) |
| \(Re\) | Duct Reynolds number | - |
| \(h\) | Air-side coefficient (each duct wall) | W/(m²·K) |
| \(h_r\) | Radiation coefficient across the duct | W/(m²·K) |
| \(F'\) | Collector efficiency factor | - |
| \(F''\) | Collector flow factor | - |
| \(F_R\) | Heat removal factor | - |
| \(Q_u\) | Useful gain | W |
| \(T_o\) | Outlet air temperature | K |
| \(\eta\) | Collector efficiency | - |
| \(T_{fm}\) | Mean air temperature | K |
| \(T_{pm}\) | Mean absorber temperature | K |
Method and standards
Hottel–Whillier analysis of an air heater with the duct behind the absorber.
Where it is used
- Solar crop and timber dryers.
- Space-heating air collectors.
- Process air preheating.
Common mistakes
- Using the water-collector F′ formula.
- Ignoring radiation between absorber and back plate.
Assumptions and limits
- Steady state; uniform flow; U_t entered for the absorber temperature.
Questions and answers
Why is the radiation coefficient in F′?
The absorber also heats the back plate by radiation, and the back plate passes that heat to the air, so the air sees an extra parallel path.
Why are air heaters less efficient than water collectors?
Air-side coefficients are low (tens of W/(m²·K)), which lowers F′ and so F_R.
What do the defaults represent?
An illustrative case: Crop dryer collector: 2 m x 6 m, 50 mm channel, 0.15 kg/s, ambient inlet. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 6.14, Fig. 6.14.1(b) and Example 6.14.1