Worked example
Example: Water loop, 20 m2, 0.3 kg/s, 30 m of 28 mm pipe each way, U 1.2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Collector area | 20.000 m² |
| Collector F_R(τα) | 70.000 % |
| Collector F_R U_L | 4.5000 W/(m²·K) |
| Capacitance rate of the collector fluid | 1.2540 kW/K |
| Pipe or duct loss coefficient (on its surface area) | 1.2000 W/(m²·K) |
| Inlet (supply) pipe or duct surface area | 5.6549 m² |
| Outlet (return) pipe or duct surface area | 5.6549 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Optical factor ratio | 0.99462 |
| Loss coefficient ratio | 1.1392 |
| Modified intercept | 69.623 % |
| Modified slope | 5.1265 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(\frac{(\tau\alpha)'}{(\tau\alpha)} = \frac{1}{1 + \frac{U_dA_o}{\dot mc_p}}, \quad \frac{U'_L}{U_L} = \frac{1 - \frac{U_dA_o}{\dot mc_p} + \frac{U_d(A_i + A_o)}{A_cF_RU_L}}{1 + \frac{U_dA_o}{\dot mc_p}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A_c\) | Collector area | m² |
| \(F_R(\tau\alpha)\) | Collector F_R(τα) | - |
| \(F_RU_L\) | Collector F_R U_L | W/(m²·K) |
| \(\dot mc_p\) | Capacitance rate of the collector fluid | W/K |
| \(U_d\) | Pipe or duct loss coefficient (on its surface area) | W/(m²·K) |
| \(A_i\) | Inlet (supply) pipe or duct surface area | m² |
| \(A_o\) | Outlet (return) pipe or duct surface area | m² |
| \((\tau\alpha)'/(\tau\alpha)\) | Optical factor ratio | - |
| \(U'_L/U_L\) | Loss coefficient ratio | - |
| \(F_R(\tau\alpha)'\) | Modified intercept | - |
| \(F_RU'_L\) | Modified slope | W/(m²·K) |
Method and standards
The equivalent-collector treatment of pipe and duct losses.
Where it is used
- Deciding pipe insulation in solar loops.
- f-chart inputs for systems with long runs.
Common mistakes
- Using the pipe length instead of its surface area.
- Ignoring losses from long air ducts.
Assumptions and limits
- Small temperature change along the pipes; ambient surroundings.
Questions and answers
How do I get U_d?
From the pipe's insulation: U_d is the loss per square metre of pipe surface per kelvin, about 1 W/(m²·K) for 30–40 mm of insulation and near 10 W/(m²·K) bare.
Why does the return pipe affect the optical factor?
Heat lost after the collector reduces the delivered gain in proportion to the gain itself, which looks like a lower (τα).
What do the defaults represent?
An illustrative case: Water loop, 20 m2, 0.3 kg/s, 30 m of 28 mm pipe each way, U 1.2. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 10.3, eqs. 10.3.9 and 10.3.10 (Beckman, 1978) and Example 10.3.1