FireCADCalc

Flat-Plate Collector F, F' and FR: Useful Gain and Outlet Temperature

Fin efficiency, collector efficiency factor, flow factor and heat removal factor of a tube-and-sheet collector, with useful gain, outlet temperature and efficiency.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Aluminium fin 0.4 mm, 100 mm pitch, bond 30 W/(m K), 2.5 m2, 0.02 kg/sLosses exceed gain: low sun, inlet 80 C

Accepted: 0.5 to 30 W/(m²·K)
Accepted: 10 to 1,000 mm
Accepted: 2 to 100 mm
Accepted: 2 to 100 mm
Accepted: 0.1 to 10 mm
Accepted: 1 to 500 W/(m·K)
Accepted: 0 to 1,000,000 W/m
Accepted: 1 to 100,000 W/(m²·K)
Accepted: 0.1 to 10,000 m²
Accepted: 1E-5 to 100 kg/s
Accepted: 0.5 to 5 kJ/(kg·K)
Accepted: 0 to 1,500 W/m²
Accepted: 1 to 1,500 W/m²
Accepted: -23.15 to 226.85 °C
Accepted: -43.15 to 56.85 °C

Results

Hottel–Whillier–Bliss analysis for a sheet-and-tube absorber with uniform flow; F' depends on geometry and h_fi, F'' only on the capacitance ratio ṁc_p/(A_c U_L F').

Fin parameter7.30191/m
Fin efficiency96.696%
Collector efficiency factor94.404%
Collector flow factor93.909%
Heat removal factor88.654%
Useful gain1,302.1W
Useful gain per unit area520.84W/m²
Outlet temperature65.575°C
Collector efficiency57.871%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Aluminium fin 0.4 mm, 100 mm pitch, bond 30 W/(m K), 2.5 m2, 0.02 kg/s. The inputs, in the units selected above:

InputValue
Overall loss coefficient4.5000 W/(m²·K)
Tube spacing100.00 mm
Tube outside diameter12.000 mm
Tube inside diameter10.000 mm
Plate (fin) thickness0.40000 mm
Plate conductivity (copper 385, aluminium 211)211.00 W/(m·K)
Bond conductance per unit length (0 = perfect bond)30.000 W/m
Heat transfer coefficient inside the tubes1,000.0 W/(m²·K)
Collector area2.5000 m²
Fluid flow through the collector0.020000 kg/s
Fluid specific heat4.1800 kJ/(kg·K)
Absorbed solar radiation per unit area700.00 W/m²
Incident radiation on the collector (for efficiency)900.00 W/m²
Fluid inlet temperature50.000 °C
Ambient temperature25.000 °C

Applying the formula below gives:

ResultValue
Fin parameter7.3019 1/m
Fin efficiency96.696 %
Collector efficiency factor94.404 %
Collector flow factor93.909 %
Heat removal factor88.654 %
Useful gain1,302.1 W
Useful gain per unit area520.84 W/m²
Outlet temperature65.575 °C
Collector efficiency57.871 %

Open this example in the calculator and change any input.

Formula

\(F = \frac{\tanh[m(W - D)/2]}{m(W - D)/2}, \quad m = \sqrt{\frac{U_L}{k\delta}}, \quad F' = \frac{1/U_L}{W\left[\frac{1}{U_L[D + (W - D)F]} + \frac{1}{C_b} + \frac{1}{\pi D_ih_{fi}}\right]}\)

\(F_R = F'F'' = \frac{\dot mc_p}{A_cU_L}\left[1 - \exp\left(-\frac{A_cU_LF'}{\dot mc_p}\right)\right], \quad Q_u = A_cF_R[S - U_L(T_i - T_a)]\)

Variables

Symbol Meaning SI unit
\(U_L\) Overall loss coefficient W/(m²·K)
\(W\) Tube spacing m
\(D\) Tube outside diameter m
\(D_i\) Tube inside diameter m
\(\delta\) Plate (fin) thickness m
\(k\) Plate conductivity (copper 385, aluminium 211) W/(m·K)
\(C_b\) Bond conductance per unit length (0 = perfect bond) W/m
\(h_{fi}\) Heat transfer coefficient inside the tubes W/(m²·K)
\(A_c\) Collector area m²
\(\dot m\) Fluid flow through the collector kg/s
\(c_p\) Fluid specific heat J/(kg·K)
\(S\) Absorbed solar radiation per unit area W/m²
\(G_T\) Incident radiation on the collector (for efficiency) W/m²
\(T_i\) Fluid inlet temperature K
\(T_a\) Ambient temperature K
\(m\) Fin parameter 1/m
\(F\) Fin efficiency -
\(F'\) Collector efficiency factor -
\(F''\) Collector flow factor -
\(F_R\) Heat removal factor -
\(Q_u\) Useful gain W
\(q_u\) Useful gain per unit area W/m²
\(T_o\) Outlet temperature K
\(\eta\) Collector efficiency -

Method and standards

Hottel–Whillier–Bliss flat-plate collector theory.

Where it is used

  • Designing absorber plates and choosing flow rates.
  • Hour-by-hour collector output in system studies.

Common mistakes

  • Using G_T instead of the absorbed S = G_T(τα) in the gain equation.
  • Using outlet or mean temperature where the equation needs the inlet temperature.

Assumptions and limits

  • Steady state, uniform flow in parallel tubes, constant U_L.

Questions and answers

What does F_R mean physically?

It is the ratio of the actual useful gain to the gain if the whole absorber were at the fluid inlet temperature, the lowest-loss condition.

How do I raise F'?

Closer tube spacing, thicker or more conductive plate, a good bond and turbulent flow in the tubes; copper sheet 0.5 mm at 150 mm spacing gives about 0.84.

What do the defaults represent?

An illustrative case: Aluminium fin 0.4 mm, 100 mm pitch, bond 30 W/(m K), 2.5 m2, 0.02 kg/s. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), secs. 6.5 to 6.7, eqs. 6.5.12, 6.5.18, 6.7.5 and 6.7.6, Examples 6.5.1 and 6.7.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.