Worked example
Example: Air system, 30 m2, 15 L/s per m2, 0.3 m3 pebbles per m2, March. The inputs, in the units selected above:
| Input | Value |
|---|---|
| System type | Air, space and water heating (pebble bed) |
| Collector area | 30.000 m² |
| Collector F_R(τα)_n | 50.000 % |
| Collector F_R U_L | 2.9000 W/(m²·K) |
| Heat exchanger and pipe factor | 100.00 % |
| Monthly average to normal (τα) ratio (one cover 0.96, two 0.94) | 93.000 % |
| Monthly average daily radiation on the collector | 15.800 MJ/m² |
| Days in the month | 31.000 - |
| Monthly average ambient temperature | 1.0000 °C |
| Monthly heating and hot-water load | 20.000 GJ |
| Storage per m² of collector, litres of water (liquid; standard 75) | 75.000 - |
| Load heat exchanger parameter (liquid space heating; standard 2) | 2.0000 - |
| Air flow per m² of collector, L/s (air; standard 10) | 15.000 - |
| Pebble bed per m² of collector, m³ (air; standard 0.25) | 0.30000 - |
| Hot water delivery temperature (water only) | 60.000 °C |
| Mains water temperature (water only) | 11.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Loss group X | 1.1535 |
| Gain group Y | 0.34164 |
| Corrected X | 1.2234 |
| Corrected Y | 0.34164 |
| Fraction of the month's load met by solar | 25.965 % |
| Solar energy delivered in the month | 5.1929 GJ |
Open this example in the calculator and change any input.
Formula
\(X = F_RU_L\frac{F'_R}{F_R}(T_{ref} - \bar T_a)\Delta t\frac{A_c}{L}, \quad Y = F_R(\tau\alpha)_n\frac{F'_R}{F_R}\frac{(\bar{\tau\alpha})}{(\tau\alpha)_n}\bar H_TN\frac{A_c}{L}, \quad T_{ref} = 100\,^\circ\text{C}\)
\(f_{liquid} = 1.029Y - 0.065X - 0.245Y^2 + 0.0018X^2 + 0.0215Y^3, \quad f_{air} = 1.040Y - 0.065X - 0.159Y^2 + 0.00187X^2 - 0.0095Y^3\)
\(\frac{X_c}{X} = \left(\frac{V_s}{75}\right)^{-0.25}, \quad \frac{Y_c}{Y} = 0.39 + 0.65e^{-0.139(UA)_h/\varepsilon_LC_{min}}, \quad \frac{X_c}{X} = \frac{11.6 + 1.18T_w + 3.86T_m - 2.32\bar T_a}{100 - \bar T_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{system}\) | System type | - |
| \(A_c\) | Collector area | m² |
| \(F_R(\tau\alpha)_n\) | Collector F_R(τα)_n | - |
| \(F_RU_L\) | Collector F_R U_L | W/(m²·K) |
| \(F'_R/F_R\) | Heat exchanger and pipe factor | - |
| \((\bar{\tau\alpha})/(\tau\alpha)_n\) | Monthly average to normal (τα) ratio (one cover 0.96, two 0.94) | - |
| \(\bar H_T\) | Monthly average daily radiation on the collector | J/m² |
| \(N\) | Days in the month | - |
| \(\bar T_a\) | Monthly average ambient temperature | K |
| \(L\) | Monthly heating and hot-water load | J |
| \(V_s/A_c\) | Storage per m² of collector, litres of water (liquid; standard 75) | - |
| \(\varepsilon_LC_{min}/(UA)_h\) | Load heat exchanger parameter (liquid space heating; standard 2) | - |
| \(\dot V/A_c\) | Air flow per m² of collector, L/s (air; standard 10) | - |
| \(V_p/A_c\) | Pebble bed per m² of collector, m³ (air; standard 0.25) | - |
| \(T_w\) | Hot water delivery temperature (water only) | K |
| \(T_m\) | Mains water temperature (water only) | K |
| \(X\) | Loss group X | - |
| \(Y\) | Gain group Y | - |
| \(X_c\) | Corrected X | - |
| \(Y_c\) | Corrected Y | - |
| \(f\) | Fraction of the month's load met by solar | - |
| \(fL\) | Solar energy delivered in the month | J |
Method and standards
f-chart correlations of Klein, from TRNSYS simulations.
Where it is used
- Sizing collector area for domestic and institutional hot water.
- Annual solar fraction for space-heating systems.
Common mistakes
- Using daily instead of monthly totals.
- Forgetting tank losses in the water heating load.
- Using it for loads well above 60 °C.
Assumptions and limits
- Standard system configurations; monthly averages; X and Y within the fitted range.
Questions and answers
What do X and Y mean?
Y compares the energy absorbed by the collectors in the month with the load; X compares the collector's reference losses (at 100 °C) with the load.
Can the f-chart be used for process heat?
Only for loads near 20 °C (space heating) or hot water up to about 60–70 °C; higher minimum temperatures need the φ̄,f-chart or simulation.
What do the defaults represent?
An illustrative case: Air system, 30 m2, 15 L/s per m2, 0.3 m3 pebbles per m2, March. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.