FireCADCalc

Parabolic Trough Receiver: F', FR, Useful Gain and Outlet Temperature

Collector efficiency factor, heat removal factor, useful gain and outlet temperature of a cylindrical receiver in a linear parabolic trough concentrator.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Same trough at the stated inlet 155.2 CProcess-heat trough 1.8 m x 50 m, 35 mm receiver, water 0.4 kg/s at 120 C

Accepted: 0.2 to 10 m
Accepted: 1 to 1,000 m
Accepted: 0 to 500 mm
Accepted: 0 to 1.2 kW/m²
Accepted: 5 to 300 mm
Accepted: 4 to 300 mm
Accepted: 1 to 400 W/(m·K)
Accepted: 10 to 100,000 W/(m²·K)
Accepted: 0.1 to 100 W/(m²·K)
Accepted: 0.0001 to 100 kg/s
Accepted: 0.5 to 6 kJ/(kg·K)
Accepted: 0 to 626.85 °C
Accepted: -43.15 to 56.85 °C

Results

S already includes reflectance, intercept factor and (τα); U_L is based on the receiver area and usually comes from a receiver test or the envelope heat balance.

Receiver area1.8850m²
Unshaded aperture area24.100m²
Concentration ratio A_a/A_r12.785
Collector efficiency factor98.368%
Flow factor98.004%
Heat removal factor96.405%
Useful gain8.9825kW
Outlet temperature206.51°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Same trough at the stated inlet 155.2 C. The inputs, in the units selected above:

InputValue
Aperture width2.5000 m
Collector length10.000 m
Glass envelope outer diameter (shades the aperture)90.000 mm
Absorbed radiation per unit aperture area0.43000 kW/m²
Absorber outside diameter60.000 mm
Absorber inside diameter50.000 mm
Absorber tube conductivity16.000 W/(m·K)
Inside coefficient300.00 W/(m²·K)
Receiver loss coefficient (on receiver area)3.8200 W/(m²·K)
Fluid flow0.053700 kg/s
Fluid specific heat3.2600 kJ/(kg·K)
Fluid inlet temperature155.20 °C
Ambient temperature10.000 °C

Applying the formula below gives:

ResultValue
Receiver area1.8850 m²
Unshaded aperture area24.100 m²
Concentration ratio A_a/A_r12.785
Collector efficiency factor98.368 %
Flow factor98.004 %
Heat removal factor96.405 %
Useful gain8.9825 kW
Outlet temperature206.51 °C

Open this example in the calculator and change any input.

Formula

\(F' = \frac{1/U_L}{\frac{1}{U_L} + \frac{D_o}{h_{fi}D_i} + \frac{D_o}{2k}\ln\frac{D_o}{D_i}}, \quad F_R = \frac{\dot mc_p}{A_rU_L}\left[1 - \exp\left(-\frac{A_rU_LF'}{\dot mc_p}\right)\right]\)

\(Q_u = F_RA_a\left[S - \frac{A_r}{A_a}U_L(T_i - T_a)\right]\)

Variables

Symbol Meaning SI unit
\(W_a\) Aperture width m
\(L\) Collector length m
\(D_g\) Glass envelope outer diameter (shades the aperture) m
\(S\) Absorbed radiation per unit aperture area W/m²
\(D_o\) Absorber outside diameter m
\(D_i\) Absorber inside diameter m
\(k\) Absorber tube conductivity W/(m·K)
\(h_{fi}\) Inside coefficient W/(m²·K)
\(U_L\) Receiver loss coefficient (on receiver area) W/(m²·K)
\(\dot m\) Fluid flow kg/s
\(c_p\) Fluid specific heat J/(kg·K)
\(T_i\) Fluid inlet temperature K
\(T_a\) Ambient temperature K
\(A_r\) Receiver area m²
\(A_a\) Unshaded aperture area m²
\(C\) Concentration ratio A_a/A_r -
\(F'\) Collector efficiency factor -
\(F''\) Flow factor -
\(F_R\) Heat removal factor -
\(Q_u\) Useful gain W
\(T_o\) Outlet temperature K

Method and standards

Hottel–Whillier analysis applied to a concentrating collector.

Where it is used

  • Parabolic trough loop performance.
  • Industrial process heat collectors.

Common mistakes

  • Using aperture area for losses.
  • Using DNI instead of absorbed radiation S.

Assumptions and limits

  • Steady state; uniform flux around the receiver assumed in F'.

Questions and answers

Why are losses written per receiver area?

Heat is lost only from the small receiver; concentration C = A_a/A_r cuts the loss per unit aperture, which is why concentrators reach high temperatures.

Why is the glass envelope subtracted from the aperture?

It shades the central strip of the mirror from the beam.

What do the defaults represent?

An illustrative case: Same trough at the stated inlet 155.2 C. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 7.3, eqs. 7.3.9 to 7.3.12 and Example 7.3.2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.