Worked example
Example: Illustrative 3000 m2, 70 C storage. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean solar irradiance on the pond | 0.23000 kW/m² |
| Fraction of light reaching the storage zone | 40.000 % |
| Overall heat loss coefficient of the storage zone | 0.80000 W/(m²·K) |
| Storage zone temperature | 70.000 °C |
| Ambient (surface) temperature | 20.000 °C |
| Pond area | 3,000.0 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Collection efficiency | 22.609 % |
| Useful heat | 156.00 kW |
| Useful heat per year | 1,367.5 MWh |
| Stagnation temperature (no extraction) | 135.00 °C |
Open this example in the calculator and change any input.
Formula
\(\eta = \tau - \frac{U(T_s - T_a)}{\bar G}, \quad T_{stag} = T_a + \frac{\tau\bar G}{U}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\bar G\) | Mean solar irradiance on the pond | W/m² |
| \(\tau\) | Fraction of light reaching the storage zone | - |
| \(U\) | Overall heat loss coefficient of the storage zone | W/(m²·K) |
| \(T_s\) | Storage zone temperature | K |
| \(T_a\) | Ambient (surface) temperature | K |
| \(A\) | Pond area | m² |
| \(\eta\) | Collection efficiency | - |
| \(\dot Q\) | Useful heat | W |
| \(Q_a\) | Useful heat per year | J |
| \(T_{stag}\) | Stagnation temperature (no extraction) | K |
Method and standards
Solar pond balance.
Where it is used
- Process heat and desalination screening.
- Teaching solar thermal storage.
Common mistakes
- Using peak instead of annual mean irradiance.
- Ignoring ground losses in U.
Assumptions and limits
- Steady annual average; well-maintained gradient.
References
- Solar pond collection efficiency
Questions and answers
How does a solar pond trap heat?
Salt makes the bottom water denser even when it is hot, so it does not rise and lose heat; the gradient layer above acts as insulation.
What can the heat be used for?
Low-temperature process heat, desalination, space heating and small organic Rankine cycles.
What do the defaults represent?
An illustrative 3,000 m² pond with 230 W/m² mean sun, 40 % reaching the storage zone, U = 0.8 W/(m²·K), storage at 70 °C and air at 20 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), ch. 6, Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)