FireCADCalc

Effective Sky Temperature and Radiation Loss to the Sky

Effective clear-sky temperature by Berdahl and Martin from air and dew point temperatures, sky emissivity and the radiation loss of a surface facing the sky.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Clear night, 20 C air, 10 C dew point, glass at 30 C facing upHot humid afternoon, 32 C, dew point 26 C, 15:00, roof at 45 CCold dry dawn, -5 C, dew point -15 C, 06:00, collector at 0 C, 45 deg

Accepted: -43.15 to 56.85 °C
Accepted: -43.15 to 46.85 °C
Accepted: 0 to 24 h
Accepted: -43.15 to 226.85 °C
Accepted: 1 to 100 %
Accepted: 0 to 90 °

Results

Clear sky. Clouds raise the sky temperature; Berdahl and Martin's data covered dew points from −20 to 30 °C.

For a tilted surface the sky view factor (1 + cos β)/2 is applied; exchange with the ground is not included.

Effective sky temperature-32.989°C
Sky depression below air temperature27.989K
Sky emissivity0.64343
Net radiation to the sky per unit area95.411W/m²
Radiation coefficient to the sky2.8922W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Clear night, 20 C air, 10 C dew point, glass at 30 C facing up. The inputs, in the units selected above:

InputValue
Air temperature20.000 °C
Dew point temperature10.000 °C
Hour from midnight0 h
Surface temperature30.000 °C
Surface long-wave emittance (glass 0.88)88.000 %
Surface slope (0 = horizontal)0 °

Applying the formula below gives:

ResultValue
Effective sky temperature2.9872 °C
Sky depression below air temperature17.013 K
Sky emissivity0.78730
Net radiation to the sky per unit area131.30 W/m²
Radiation coefficient to the sky4.8606 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(T_{sky} = T_a\left[0.711 + 0.0056T_{dp} + 0.000073T_{dp}^2 + 0.013\cos(15t)\right]^{1/4}\)

\(q = \varepsilon\sigma\frac{1 + \cos\beta}{2}(T^4 - T_{sky}^4)\)

Variables

Symbol Meaning SI unit
\(T_a\) Air temperature K
\(T_{dp}\) Dew point temperature K
\(t\) Hour from midnight s
\(T_{surf}\) Surface temperature K
\(\varepsilon\) Surface long-wave emittance (glass 0.88) -
\(\beta\) Surface slope (0 = horizontal) rad
\(T_{sky}\) Effective sky temperature K
\(T_a - T_{sky}\) Sky depression below air temperature K
\(\varepsilon_{sky}\) Sky emissivity -
\(q_{rad}\) Net radiation to the sky per unit area W/m²
\(h_{r,s}\) Radiation coefficient to the sky W/(m²·K)

Method and standards

Berdahl and Martin (1984) clear-sky correlation; T in kelvin, T_dp in °C, t hours from midnight.

Where it is used

  • Top loss of collectors and unglazed absorbers.
  • Radiative cooling and frost risk assessment.

Common mistakes

  • Using air temperature as the sky temperature.
  • Entering the dew point in kelvin in the correlation.

Assumptions and limits

  • Clear skies only.

Questions and answers

Why is the sky colder than the air?

The atmosphere is partly transparent in the 8–13 µm window, so a surface radiates partly to cold space; dry air makes the sky colder.

Does it matter for collectors?

Only a little for glazed collectors, but it governs night-time radiative cooling, frost on surfaces and unglazed collector losses.

What do the defaults represent?

A clear night at midnight with air at 20 °C and dew point 10 °C, and a glass surface at 30 °C facing up: the sky is about 7 °C, some 13 K below the air.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 3.9, eq. 3.9.2 (Berdahl and Martin, 1984)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.