Worked example
Example: Clear night, 20 C air, 10 C dew point, glass at 30 C facing up. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Air temperature | 20.000 °C |
| Dew point temperature | 10.000 °C |
| Hour from midnight | 0 h |
| Surface temperature | 30.000 °C |
| Surface long-wave emittance (glass 0.88) | 88.000 % |
| Surface slope (0 = horizontal) | 0 ° |
Applying the formula below gives:
| Result | Value |
|---|---|
| Effective sky temperature | 2.9872 °C |
| Sky depression below air temperature | 17.013 K |
| Sky emissivity | 0.78730 |
| Net radiation to the sky per unit area | 131.30 W/m² |
| Radiation coefficient to the sky | 4.8606 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(T_{sky} = T_a\left[0.711 + 0.0056T_{dp} + 0.000073T_{dp}^2 + 0.013\cos(15t)\right]^{1/4}\)
\(q = \varepsilon\sigma\frac{1 + \cos\beta}{2}(T^4 - T_{sky}^4)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_a\) | Air temperature | K |
| \(T_{dp}\) | Dew point temperature | K |
| \(t\) | Hour from midnight | s |
| \(T_{surf}\) | Surface temperature | K |
| \(\varepsilon\) | Surface long-wave emittance (glass 0.88) | - |
| \(\beta\) | Surface slope (0 = horizontal) | rad |
| \(T_{sky}\) | Effective sky temperature | K |
| \(T_a - T_{sky}\) | Sky depression below air temperature | K |
| \(\varepsilon_{sky}\) | Sky emissivity | - |
| \(q_{rad}\) | Net radiation to the sky per unit area | W/m² |
| \(h_{r,s}\) | Radiation coefficient to the sky | W/(m²·K) |
Method and standards
Berdahl and Martin (1984) clear-sky correlation; T in kelvin, T_dp in °C, t hours from midnight.
Where it is used
- Top loss of collectors and unglazed absorbers.
- Radiative cooling and frost risk assessment.
Common mistakes
- Using air temperature as the sky temperature.
- Entering the dew point in kelvin in the correlation.
Assumptions and limits
- Clear skies only.
Questions and answers
Why is the sky colder than the air?
The atmosphere is partly transparent in the 8–13 µm window, so a surface radiates partly to cold space; dry air makes the sky colder.
Does it matter for collectors?
Only a little for glazed collectors, but it governs night-time radiative cooling, frost on surfaces and unglazed collector losses.
What do the defaults represent?
A clear night at midnight with air at 20 °C and dew point 10 °C, and a glass surface at 30 °C facing up: the sky is about 7 °C, some 13 K below the air.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 3.9, eq. 3.9.2 (Berdahl and Martin, 1984)