FireCADCalc

Pebble Bed (Rock Bed) Storage: Heat Transfer, Biot Number and NTU

Volumetric heat transfer coefficient, Biot number, number of transfer units and storage capacity of a packed rock bed for solar air heating systems.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Crop dryer store: 1.0 m bed, 4 m2, 0.15 m/s, 25 mm gravelCoarse rock 60 mm, 2.5 m, 20 m2, 0.3 m/s (Bi above 0.1)

Accepted: 0.1 to 20 m
Accepted: 0.01 to 1,000 m²
Accepted: 0.001 to 2 m/s
Accepted: 0.5 to 2 kg/m³
Accepted: 0.9 to 1.2 kJ/(kg·K)
Accepted: 2 to 200 mm
Accepted: 20 to 70 %
Accepted: 500 to 5,000 kg/m³
Accepted: 0.3 to 3 kJ/(kg·K)
Accepted: 0.1 to 10 W/(m·K)
Accepted: 0.01 to 2 m²/L
Accepted: 1 to 300 K

Results

Löf and Hawley (1948) correlation h_v = 650(G/D)^0.7 in W/(m³·K) with G in kg/(m²·s) and D in m. Bi below 0.1 means negligible gradients inside the pebbles; NTU above about 10 allows the simple infinite-NTU model.

Bi exceeds 0.1: use the effective NTU with internal resistance (NTU_c).

Air mass velocity0.33000kg/(m²·s)
Volumetric heat transfer coefficient, W/(m³·K)2,143.7
Surface coefficient36.961W/(m²·K)
Biot number0.73921
Number of transfer units16.127
Heat stored over the swing3,227.7MJ

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Crop dryer store: 1.0 m bed, 4 m2, 0.15 m/s, 25 mm gravel. The inputs, in the units selected above:

InputValue
Bed length in the flow direction1.0000 m
Bed cross-section4.0000 m²
Superficial air velocity0.15000 m/s
Air density1.1500 kg/m³
Air specific heat1.0070 kJ/(kg·K)
Equivalent pebble diameter25.000 mm
Void fraction40.000 %
Pebble density2,600.0 kg/m³
Pebble specific heat0.84000 kJ/(kg·K)
Pebble conductivity2.0000 W/(m·K)
Pebble surface area per bed volume0.14400 m²/L
Temperature swing of the bed40.000 K

Applying the formula below gives:

ResultValue
Air mass velocity0.17250 kg/(m²·s)
Volumetric heat transfer coefficient, W/(m³·K)2,512.5
Surface coefficient17.448 W/(m²·K)
Biot number0.10905
Number of transfer units14.464
Heat stored over the swing209.66 MJ

Open this example in the calculator and change any input.

Formula

\(h_v = 650\left(\frac{G}{D}\right)^{0.7}, \quad Bi = \frac{h(D/2)}{k_s}, \quad NTU = \frac{h_vAL}{\dot mc_p}\)

\(Q_{st} = (1 - \varepsilon)\rho_sc_sAL\Delta T\)

Variables

Symbol Meaning SI unit
\(L\) Bed length in the flow direction m
\(A\) Bed cross-section m²
\(V\) Superficial air velocity m/s
\(\rho_a\) Air density kg/m³
\(c_{p,a}\) Air specific heat J/(kg·K)
\(D\) Equivalent pebble diameter m
\(\varepsilon\) Void fraction -
\(\rho_s\) Pebble density kg/m³
\(c_s\) Pebble specific heat J/(kg·K)
\(k_s\) Pebble conductivity W/(m·K)
\(a\) Pebble surface area per bed volume m²/m³
\(\Delta T\) Temperature swing of the bed K
\(G\) Air mass velocity kg/(m²·s)
\(h_v\) Volumetric heat transfer coefficient, W/(m³·K) -
\(h\) Surface coefficient W/(m²·K)
\(Bi\) Biot number -
\(NTU\) Number of transfer units -
\(Q_{st}\) Heat stored over the swing J

Method and standards

Packed-bed heat transfer and storage.

Where it is used

  • Sizing rock-bed stores for solar air heating and crop drying.
  • Checking whether stratification models apply.

Common mistakes

  • Using the interstitial instead of the superficial velocity.
  • Forgetting the void fraction in the capacity.

Assumptions and limits

  • Randomly packed rocks; Löf–Hawley range of sizes.

Questions and answers

Why are rock beds used with air collectors?

Air heats the rocks directly with a very large area and the bed stays stratified, so the collector receives cold air at the start of each day.

How big should the bed be?

About 0.15–0.35 m³ of pebbles per m² of collector (the f-chart standard is 0.25).

What do the defaults represent?

An illustrative case: Crop dryer store: 1.0 m bed, 4 m2, 0.15 m/s, 25 mm gravel. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), secs. 3.16 and 8.5, eq. 8.5.5 (Löf and Hawley, 1948) and Example 8.5.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.