Worked example
Example: Crop dryer store: 1.0 m bed, 4 m2, 0.15 m/s, 25 mm gravel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bed length in the flow direction | 1.0000 m |
| Bed cross-section | 4.0000 m² |
| Superficial air velocity | 0.15000 m/s |
| Air density | 1.1500 kg/m³ |
| Air specific heat | 1.0070 kJ/(kg·K) |
| Equivalent pebble diameter | 25.000 mm |
| Void fraction | 40.000 % |
| Pebble density | 2,600.0 kg/m³ |
| Pebble specific heat | 0.84000 kJ/(kg·K) |
| Pebble conductivity | 2.0000 W/(m·K) |
| Pebble surface area per bed volume | 0.14400 m²/L |
| Temperature swing of the bed | 40.000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air mass velocity | 0.17250 kg/(m²·s) |
| Volumetric heat transfer coefficient, W/(m³·K) | 2,512.5 |
| Surface coefficient | 17.448 W/(m²·K) |
| Biot number | 0.10905 |
| Number of transfer units | 14.464 |
| Heat stored over the swing | 209.66 MJ |
Open this example in the calculator and change any input.
Formula
\(h_v = 650\left(\frac{G}{D}\right)^{0.7}, \quad Bi = \frac{h(D/2)}{k_s}, \quad NTU = \frac{h_vAL}{\dot mc_p}\)
\(Q_{st} = (1 - \varepsilon)\rho_sc_sAL\Delta T\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Bed length in the flow direction | m |
| \(A\) | Bed cross-section | m² |
| \(V\) | Superficial air velocity | m/s |
| \(\rho_a\) | Air density | kg/m³ |
| \(c_{p,a}\) | Air specific heat | J/(kg·K) |
| \(D\) | Equivalent pebble diameter | m |
| \(\varepsilon\) | Void fraction | - |
| \(\rho_s\) | Pebble density | kg/m³ |
| \(c_s\) | Pebble specific heat | J/(kg·K) |
| \(k_s\) | Pebble conductivity | W/(m·K) |
| \(a\) | Pebble surface area per bed volume | m²/m³ |
| \(\Delta T\) | Temperature swing of the bed | K |
| \(G\) | Air mass velocity | kg/(m²·s) |
| \(h_v\) | Volumetric heat transfer coefficient, W/(m³·K) | - |
| \(h\) | Surface coefficient | W/(m²·K) |
| \(Bi\) | Biot number | - |
| \(NTU\) | Number of transfer units | - |
| \(Q_{st}\) | Heat stored over the swing | J |
Method and standards
Packed-bed heat transfer and storage.
Where it is used
- Sizing rock-bed stores for solar air heating and crop drying.
- Checking whether stratification models apply.
Common mistakes
- Using the interstitial instead of the superficial velocity.
- Forgetting the void fraction in the capacity.
Assumptions and limits
- Randomly packed rocks; Löf–Hawley range of sizes.
Questions and answers
Why are rock beds used with air collectors?
Air heats the rocks directly with a very large area and the bed stays stratified, so the collector receives cold air at the start of each day.
How big should the bed be?
About 0.15–0.35 m³ of pebbles per m² of collector (the f-chart standard is 0.25).
What do the defaults represent?
An illustrative case: Crop dryer store: 1.0 m bed, 4 m2, 0.15 m/s, 25 mm gravel. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), secs. 3.16 and 8.5, eq. 8.5.5 (Löf and Hawley, 1948) and Example 8.5.1