Worked example
Example: Illustrative reformer gas at 350 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reactor exit temperature | 350.00 °C |
| CO in feed (mol) | 10.000 - |
| Steam in feed (mol) | 30.000 - |
| CO₂ in feed (mol) | 5.0000 - |
| H₂ in feed (mol) | 45.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Equilibrium constant | 20.414 |
| Equilibrium CO conversion | 83.814 % |
| Extent of reaction (mol) | 8.3814 |
| CO in the dry exit gas | 2.3670 % |
| H₂ in the dry exit gas | 78.064 % |
Open this example in the calculator and change any input.
Formula
\(K_p = \frac{y_{CO_2}y_{H_2}}{y_{CO}y_{H_2O}} = \exp\left(\frac{4577.8}{T} - 4.33\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Reactor exit temperature | K |
| \(n_{CO}\) | CO in feed (mol) | - |
| \(n_{H_2O}\) | Steam in feed (mol) | - |
| \(n_{CO_2}\) | CO₂ in feed (mol) | - |
| \(n_{H_2}\) | H₂ in feed (mol) | - |
| \(K_p\) | Equilibrium constant | - |
| \(X_{CO}\) | Equilibrium CO conversion | - |
| \(\xi\) | Extent of reaction (mol) | - |
| \(y_{CO,dry}\) | CO in the dry exit gas | - |
| \(y_{H_2,dry}\) | H₂ in the dry exit gas | - |
Method and standards
Shift equilibrium.
Where it is used
- Hydrogen and ammonia plant design.
- Fuel processors for fuel cells.
Common mistakes
- Expecting pressure to change the conversion.
- Forgetting the CO₂ and H₂ already in the feed.
Assumptions and limits
- Ideal gas; equilibrium reached; no methanation.
References
- Water-gas shift equilibrium
Questions and answers
Why use two shift stages?
The reaction is exothermic, so equilibrium favours CO₂ and H₂ at low temperature, but kinetics are slow there; a hot stage does most of the work quickly and a cool stage finishes it.
Why must fuel cells avoid CO?
Even tens of ppm of CO poison the platinum anode of a PEM cell, so shift is followed by preferential oxidation or membranes.
What do the defaults represent?
An illustrative reformer gas of 10 CO, 30 H₂O, 5 CO₂ and 45 H₂ (mol) at 350 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Moe, Design of water-gas shift reactors, Chemical Engineering Progress 58 (1962) 33–36, Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8