Worked example
Example: Illustrative 100 kg/h, 98 %, S/C 1.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Methanol feed | 100.00 kg/h |
| Methanol conversion | 98.000 % |
| Steam-to-methanol molar ratio | 1.5000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydrogen produced | 18.498 kg/h |
| CO₂ produced | 134.60 kg/h |
| Water fed | 84.335 kg/h |
| Hydrogen per kg of methanol | 0.18498 kg/kg |
| Reaction heat duty at 25 °C | 41.888 kW |
| H₂ in dry product gas (no CO formed) | 74.619 % |
Open this example in the calculator and change any input.
Formula
\(CH_3OH + H_2O \rightarrow CO_2 + 3H_2, \quad \dot n_{H_2} = 3X\dot n_{MeOH}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{MeOH}\) | Methanol feed | kg/s |
| \(X\) | Methanol conversion | - |
| \(S/C\) | Steam-to-methanol molar ratio | - |
| \(\dot m_{H_2}\) | Hydrogen produced | kg/s |
| \(\dot m_{CO_2}\) | CO₂ produced | kg/s |
| \(\dot m_{H_2O}\) | Water fed | kg/s |
| \(m_{H_2}/m_{MeOH}\) | Hydrogen per kg of methanol | kg/kg |
| \(\dot Q\) | Reaction heat duty at 25 °C | W |
| \(y_{H_2,dry}\) | H₂ in dry product gas (no CO formed) | - |
Method and standards
Methanol reforming.
Where it is used
- Backup and portable fuel cell systems.
- Methanol as a hydrogen carrier.
Common mistakes
- Forgetting the steam feed in the water balance.
- Ignoring CO in the product for PEM cells.
Assumptions and limits
- No CO or methane formed; heat at 25 °C.
References
- Methanol steam reforming stoichiometry
Questions and answers
Why reform methanol rather than methane?
Methanol reforms at only 250–300 °C over copper catalysts, which suits small, portable and backup fuel cell systems.
How much hydrogen does methanol give?
Up to 0.188 kg per kg of methanol, of which a third of the hydrogen atoms come from the steam.
What do the defaults represent?
An illustrative 100 kg/h of methanol at 98 % conversion with 1.5 mol of steam per mol.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8