Worked example
Example: Illustrative 122 L car tank at 70 MPa, 15 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tank internal volume | 122.00 L |
| Tank pressure | 70.000 MPa |
| Gas temperature | 15.000 °C |
| Minimum (residual) pressure | 2.0000 MPa |
| Co-volume (about 7.69 × 10⁻³ m³/kg for hydrogen) | 0.007691 m³/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compressibility factor | 1.4530 |
| Hydrogen density | 40.538 kg/m³ |
| Hydrogen mass at p | 4.9457 kg |
| Usable mass down to p_min | 4.7430 kg |
| Usable energy on the lower heating value | 158.03 kWh |
| Mass if it were an ideal gas | 7.1861 kg |
Open this example in the calculator and change any input.
Formula
\(\rho = \frac{p}{RT + bp}, \quad Z = 1 + \frac{bp}{RT}, \quad m_u = V[\rho(p) - \rho(p_{min})]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Tank internal volume | m³ |
| \(p\) | Tank pressure | Pa |
| \(T\) | Gas temperature | K |
| \(p_{min}\) | Minimum (residual) pressure | Pa |
| \(b\) | Co-volume (about 7.69 × 10⁻³ m³/kg for hydrogen) | m³/kg |
| \(Z\) | Compressibility factor | - |
| \(\rho\) | Hydrogen density | kg/m³ |
| \(m\) | Hydrogen mass at p | kg |
| \(m_u\) | Usable mass down to p_min | kg |
| \(E\) | Usable energy on the lower heating value | J |
| \(m_{ideal}\) | Mass if it were an ideal gas | kg |
Method and standards
Abel–Noble real-gas density.
Where it is used
- Vehicle and tube-trailer storage sizing.
- Refuelling station buffer design.
Common mistakes
- Using the ideal-gas law at high pressure.
- Forgetting the residual gas left at minimum pressure.
Assumptions and limits
- Uniform temperature; pure hydrogen.
References
- Abel–Noble equation of state for compressed hydrogen
Questions and answers
How much hydrogen does a 700 bar car tank hold?
About 40 kg/m³ at 15 °C, so a 122 L tank holds about 5 kg, enough for roughly 500 km in a fuel cell car.
Why is the real mass less than the ideal-gas value?
Hydrogen molecules take up volume; at 700 bar Z is about 1.45, so an ideal-gas calculation overstates the mass by about 45 %.
What do the defaults represent?
An illustrative 122 L vehicle tank at 70 MPa and 15 °C, used down to 2 MPa.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8