FireCADCalc

Fuel Cell Stack Hydrogen, Air, Water and Heat

Hydrogen consumed and supplied, air flow, exit air, water produced and heat to remove for a hydrogen fuel cell stack of given power and cell voltage.

Thermal power plantChemical and fertiliser

Inputs

Examples: Illustrative 10 kW, 60 cells, 0.65 VBus 100 kW, 400 cells, 0.7 V, lambda 1.8Backup 2 kW, 30 cells, 0.6 V

Accepted: 0.001 to 100,000 kW
Accepted: 0.3 to 1.2 V
Accepted: 1 to 5,000
Accepted: 1 to 10
Accepted: 1 to 3

Results

Faraday: each H₂ molecule gives 2 electrons, so ṅ_H₂ = P_e/(2V_cF) for the whole stack. Air from the oxygen used times the stoichiometry over the oxygen fraction of dry air. Heat = P_e(1.253/V_c − 1) when water leaves as vapour (1.481 V if liquid).

Stack current111.11A
Hydrogen used0.12537kg/h
Hydrogen supplied0.12537kg/h
Air supplied10.747kg/h
Exit air (dry, oxygen depleted)9.7525kg/h
Water produced1.1203kg/h
Heat produced (water leaves as vapour)2.1770kW
Heat produced (water leaves as liquid)2.9368kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 kW, 60 cells, 0.65 V. The inputs, in the units selected above:

InputValue
Stack electrical power10.000 kW
Average cell voltage0.65000 V
Number of cells60.000 -
Air stoichiometry2.0000 -
Hydrogen stoichiometry (supplied over used)1.1000 -

Applying the formula below gives:

ResultValue
Stack current256.41 A
Hydrogen used0.57861 kg/h
Hydrogen supplied0.63647 kg/h
Air supplied39.683 kg/h
Exit air (dry, oxygen depleted)35.091 kg/h
Water produced5.1705 kg/h
Heat produced (water leaves as vapour)9.2786 kW
Heat produced (water leaves as liquid)12.785 kW

Open this example in the calculator and change any input.

Formula

\(\dot n_{H_2} = \frac{P_e}{2V_cF}, \quad \dot m_{air} = \lambda\frac{\dot n_{H_2}}{2\,y_{O_2}}M_{air}, \quad \dot Q = P_e\left(\frac{1.253}{V_c} - 1\right)\)

Variables

Symbol Meaning SI unit
\(P_e\) Stack electrical power W
\(V_c\) Average cell voltage V
\(n\) Number of cells -
\(\lambda_{air}\) Air stoichiometry -
\(\lambda_{H_2}\) Hydrogen stoichiometry (supplied over used) -
\(I\) Stack current A
\(\dot m_{H_2}\) Hydrogen used kg/s
\(\dot m_{H_2,in}\) Hydrogen supplied kg/s
\(\dot m_{air}\) Air supplied kg/s
\(\dot m_{exit}\) Exit air (dry, oxygen depleted) kg/s
\(\dot m_{H_2O}\) Water produced kg/s
\(\dot Q_{LHV}\) Heat produced (water leaves as vapour) W
\(\dot Q_{HHV}\) Heat produced (water leaves as liquid) W

Method and standards

Faraday's law and energy balance.

Where it is used

  • Stack balance-of-plant sizing (blower, humidifier, radiator).
  • Hydrogen storage sizing for vehicles and backup power.

Common mistakes

  • Forgetting the number of cells when converting power to current.
  • Using the HHV voltage when water leaves as vapour.

Assumptions and limits

  • Steady state; all current from hydrogen oxidation.

References

  • Faraday's law applied to a hydrogen fuel cell stack

Questions and answers

How much hydrogen does 1 kW need?

At 0.65 V per cell about 0.058 kg per hour, roughly 0.65 Nm³/h.

Why is so much heat produced?

At 0.65 V the stack converts only about half of the hydrogen's energy to electricity; the rest, about 1 kW of heat per kW of power, must be removed by the cooling system.

What do the defaults represent?

An illustrative 10 kW stack of 60 cells at 0.65 V with air at twice stoichiometric and 10 % excess hydrogen.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), appendix 2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.