Worked example
Example: Illustrative 10 kW, 60 cells, 0.65 V. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Stack electrical power | 10.000 kW |
| Average cell voltage | 0.65000 V |
| Number of cells | 60.000 - |
| Air stoichiometry | 2.0000 - |
| Hydrogen stoichiometry (supplied over used) | 1.1000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stack current | 256.41 A |
| Hydrogen used | 0.57861 kg/h |
| Hydrogen supplied | 0.63647 kg/h |
| Air supplied | 39.683 kg/h |
| Exit air (dry, oxygen depleted) | 35.091 kg/h |
| Water produced | 5.1705 kg/h |
| Heat produced (water leaves as vapour) | 9.2786 kW |
| Heat produced (water leaves as liquid) | 12.785 kW |
Open this example in the calculator and change any input.
Formula
\(\dot n_{H_2} = \frac{P_e}{2V_cF}, \quad \dot m_{air} = \lambda\frac{\dot n_{H_2}}{2\,y_{O_2}}M_{air}, \quad \dot Q = P_e\left(\frac{1.253}{V_c} - 1\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_e\) | Stack electrical power | W |
| \(V_c\) | Average cell voltage | V |
| \(n\) | Number of cells | - |
| \(\lambda_{air}\) | Air stoichiometry | - |
| \(\lambda_{H_2}\) | Hydrogen stoichiometry (supplied over used) | - |
| \(I\) | Stack current | A |
| \(\dot m_{H_2}\) | Hydrogen used | kg/s |
| \(\dot m_{H_2,in}\) | Hydrogen supplied | kg/s |
| \(\dot m_{air}\) | Air supplied | kg/s |
| \(\dot m_{exit}\) | Exit air (dry, oxygen depleted) | kg/s |
| \(\dot m_{H_2O}\) | Water produced | kg/s |
| \(\dot Q_{LHV}\) | Heat produced (water leaves as vapour) | W |
| \(\dot Q_{HHV}\) | Heat produced (water leaves as liquid) | W |
Method and standards
Faraday's law and energy balance.
Where it is used
- Stack balance-of-plant sizing (blower, humidifier, radiator).
- Hydrogen storage sizing for vehicles and backup power.
Common mistakes
- Forgetting the number of cells when converting power to current.
- Using the HHV voltage when water leaves as vapour.
Assumptions and limits
- Steady state; all current from hydrogen oxidation.
References
- Faraday's law applied to a hydrogen fuel cell stack
Questions and answers
How much hydrogen does 1 kW need?
At 0.65 V per cell about 0.058 kg per hour, roughly 0.65 Nm³/h.
Why is so much heat produced?
At 0.65 V the stack converts only about half of the hydrogen's energy to electricity; the rest, about 1 kW of heat per kW of power, must be removed by the cooling system.
What do the defaults represent?
An illustrative 10 kW stack of 60 cells at 0.65 V with air at twice stoichiometric and 10 % excess hydrogen.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), appendix 2